Carrier gas furnace code 14: ignition or flame loss lockout

The control locked out gas heat after repeated ignition or flame problems: 14.1 after four failed ignition tries, 14.2 after flame dropped out three times once heating was under way, and 14.3 after seven flame losses in one call for heat. It retries after three hours.

Photograph of a plain closed furnace cabinet with a metal duct in a tidy, softly lit basement
On this page
Code
14
Equipment
Carrier gas furnace
Models
59SC2E single-stage 35-inch condensing gas furnaces
What to do
Technician repair

What code 14 means

Carrier's 59SC2E Single-Stage 35-in. Tall 4-Way Multipoise High Efficiency Condensing Gas Furnace - Installation, Start-up, Operating and Service and Maintenance Instructions (59SC2E-03SI) lists 14 as ignition or flame loss lockout, for the 59SC2E single-stage 35-inch condensing gas furnaces. A three-digit display on the control board shows codes such as 33.1, and the status light seen through the sight glass in the blower door flashes the first two digits as short and long flashes.

What usually causes it

The manual points to these causes for this code, roughly in the order a technician would rule them out:

  • Manifold gas pressure or firing rate set wrong.
  • Swings in the incoming gas pressure.
  • Any of the flame proving problems listed under code 34, such as a dirty flame sensor or a closed gas shut-off.

What you can safely check

  1. Check that gas is reaching the house. If other gas appliances (stove, dryer) also do not work, the problem is the gas supply, so call your gas utility. Do not try to light anything or adjust the gas valve yourself.
  2. Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.
  3. Reset it once. Turn the unit off at its switch, wait a minute, and turn it back on, or use the reset the manual describes. One reset clears a passing glitch. If the same code comes back, stop resetting and book a technician.

When to call a technician

Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code 14 (the manual's first suspect is manifold gas pressure or firing rate set wrong). That saves a diagnostic visit from starting at zero.

Step by step for this kind of problem

The Furnace not working troubleshooter walks through the symptom question by question and ends with a clear next step.

Other Carrier gas furnace codes

The full Carrier gas furnace code table lists every code with its meaning, and explains how to read and clear them.

Sources

  1. Carrier, 59SC2E Single-Stage 35-in. Tall 4-Way Multipoise High Efficiency Condensing Gas Furnace - Installation, Start-up, Operating and Service and Maintenance Instructions (59SC2E-03SI) shareddocs.com
  2. Carrier, Furnace not turning on (help page) carrier.com
  3. U.S. Consumer Product Safety Commission, Carbon Monoxide Information Center cpsc.gov
  4. Noritz, How to troubleshoot a tankless water heater noritz.com