Carrier gas furnace code 45: control failure

The control board has an internal fault: 45.1 a flame circuit, memory or sequence error, 45.2 a gas valve relay that will not close, 45.3 a memory chip problem. Cycle power once; if 45 returns, the board is replaced.

Photograph of a plain closed furnace cabinet with a metal duct in a tidy, softly lit basement
On this page
Code
45
Equipment
Carrier gas furnace
Models
59SC2E single-stage 35-inch condensing gas furnaces
What to do
Technician repair

What code 45 means

Carrier's 59SC2E Single-Stage 35-in. Tall 4-Way Multipoise High Efficiency Condensing Gas Furnace - Installation, Start-up, Operating and Service and Maintenance Instructions (59SC2E-03SI) lists 45 as control failure, for the 59SC2E single-stage 35-inch condensing gas furnaces. A three-digit display on the control board shows codes such as 33.1, and the status light seen through the sight glass in the blower door flashes the first two digits as short and long flashes.

What usually causes it

The manual points to these causes for this code, roughly in the order a technician would rule them out:

  • A flame circuit, memory or sequence fault on the board.
  • A gas valve relay that will not close, or a memory chip error.

What you can safely check

  1. Reset it once. Turn the unit off at its switch, wait a minute, and turn it back on, or use the reset the manual describes. One reset clears a passing glitch. If the same code comes back, stop resetting and book a technician.
  2. Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.

When to call a technician

Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code 45 (the manual's first suspect is a flame circuit, memory or sequence fault on the board). That saves a diagnostic visit from starting at zero.

Step by step for this kind of problem

The Furnace not working troubleshooter walks through the symptom question by question and ends with a clear next step.

Other Carrier gas furnace codes

The full Carrier gas furnace code table lists every code with its meaning, and explains how to read and clear them.