Carrier gas furnace error codes
Carrier gas furnace code 31: secondary pressure switch open
On the 59SC2E control, code 31 covers only the secondary (housing) pressure switch; the main switch has its own code 32. The secondary switch did not close within a minute of the gas valve closing, or opened again (31.2). After three failed tries the control locks out (31.3). If it opens during the blower delay, the blower runs its normal off delay.

On this page
- Code
- 31
- Equipment
- Carrier gas furnace
- Models
- 59SC2E single-stage 35-inch condensing gas furnaces
- What to do
- Often an owner fix
What code 31 means
Carrier's 59SC2E Single-Stage 35-in. Tall 4-Way Multipoise High Efficiency Condensing Gas Furnace - Installation, Start-up, Operating and Service and Maintenance Instructions (59SC2E-03SI) lists 31 as secondary pressure switch open, for the 59SC2E single-stage 35-inch condensing gas furnaces. A three-digit display on the control board shows codes such as 33.1, and the status light seen through the sight glass in the blower door flashes the first two digits as short and long flashes.
What usually causes it
The manual points to these causes for this code, roughly in the order a technician would rule them out:
- A restricted vent or strong wind at the vent.
- A blocked or restricted condensate drain.
- Pressure tubing that is disconnected or blocked.
- A vent that is the wrong size, or too little combustion air.
- A failed inducer motor.
- Low incoming gas pressure, where a low gas pressure switch is fitted.
What you can safely check
- Look at the vent pipes outside. High-efficiency furnaces, boilers and tankless heaters breathe through plastic pipes on an outside wall or the roof. From the ground, check that snow, ice, leaves or a nest are not blocking either opening, and clear what you can reach safely.
- Look at the condensate drain. Condensing equipment makes water that drains through a small hose or trap. A kinked hose, a full pump or water pooling under the unit can make it shut down. Straighten a kinked hose and empty a full pump reservoir; leave the trap itself to a technician.
- Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.
- Reset it once. Turn the unit off at its switch, wait a minute, and turn it back on, or use the reset the manual describes. One reset clears a passing glitch. If the same code comes back, stop resetting and book a technician.
When to call a technician
Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code 31 (the manual's first suspect is a restricted vent or strong wind at the vent). That saves a diagnostic visit from starting at zero.
Step by step for this kind of problem
The Furnace not working troubleshooter walks through the symptom question by question and ends with a clear next step.
Related Carrier codes
Other Carrier gas furnace codes
The full Carrier gas furnace code table lists every code with its meaning, and explains how to read and clear them.
Sources
- Carrier, 59SC2E Single-Stage 35-in. Tall 4-Way Multipoise High Efficiency Condensing Gas Furnace - Installation, Start-up, Operating and Service and Maintenance Instructions (59SC2E-03SI) shareddocs.com
- ENERGY STAR, Maintenance Checklist (heating and cooling) energystar.gov
- Noritz, How to troubleshoot a tankless water heater noritz.com