Carrier gas furnace error codes: what each one means
Carrier's manual for the 59SC2E single-stage 35-inch condensing gas furnaces lists 16 codes. A three-digit display on the control board shows codes such as 33.1, and the status light seen through the sight glass in the blower door flashes the first two digits as short and long flashes.

On this page
- Codes listed
- 16
- Turn off and call a pro
- 4
- Often an owner fix
- 4
How to read the code
The 59SC2E control has two ways of showing a fault. The status light, visible through the sight glass in the blower access door, flashes only the major code: count the short flashes for the first digit and the long flashes for the second, so two short and four long means code 24.
The small display on the board shows the same major code plus one more digit after a dot, such as 31.3 or 34.2. That last digit is the minor code, which narrows the fault down. This table lists each major code and explains its minor numbers. Normal states show as letters instead: idL when idle, Ht when heating, CL when cooling.
The board saves the last seven faults, keeps them through a power cut, and erases them after 72 hours of powered running since the latest one. A technician reads them in the FLt menu by holding the blower door switch in, next to live wiring, so this is not an owner job. The manual warns never to tape that door switch shut.
Ignition and flame-loss lockouts (code 14) and the limit lockout (code 13) clear themselves after three hours. The burner area also has a rollout switch that must be reset by hand, and the manual says not to jumper it and to fix the cause first, such as too little combustion air, the wrong gas pressure or a venting fault.
Carrier gas furnace code table
Codes with a link have their own page with causes and the checks that fit that code.
| Code | What it means | What to do |
|---|---|---|
| 10 | Reversed power polarity. Shown as 10.1 with a fast flashing status light: the incoming 115 volt power has hot and neutral reversed, and the furnace will not run. | Technician repair |
| 12 | Heat call at power up. Code 12.1 is a normal status: power came on while the thermostat was calling for heat, so the blower runs for 90 seconds first. | Often an owner fix |
| 13 | Limit lockout. Code 13.1: a switch in the main limit circuit stayed open for more than three minutes, so the control locked out gas heat. It tries again on its own after three hours. | Turn it off and call a pro |
| 14 | Ignition or flame loss lockout. The control locked out gas heat after repeated ignition or flame problems: 14.1 after four failed ignition tries, 14.2 after flame dropped out three times once heating was under way, and 14.3 after seven flame losses in one call for heat. It retries after three hours. | Technician repair |
| 21 | Voltage on the gas valve. Code 21.1: the control found 24 volts on the gas valve at a time when the valve should be off, and locked out gas heating. Power has to be off for five minutes before it will retry. | Turn it off and call a pro |
| 22 | False flame. Code 22.1: the control senses flame while the gas valve is off. The inducer fan keeps running until the signal clears. | Turn it off and call a pro |
| 23 | Pressure switch stuck closed. A pressure switch is closed when it should be open: 23.1 is the main pressure switch and 23.2 the secondary one. | Technician repair |
| 24 | Fuse fault. Code 24.1: the 3 amp fuse on the control board has blown, cutting the 24 volt control circuit. | Technician repair |
| 25 | Control program problem. The board's model program or settings are missing, corrupt or wrong for this furnace (25.1 to 25.7). Some minors stop heating; with 25.4 and 25.5 the furnace keeps running on a backup program or default settings. | Technician repair |
| 27 | Super plug not read. Codes 27.1 to 27.3: the program plug used to load the control is missing, unreadable or corrupt, so the board cannot copy its model program. | Technician repair |
| 31 | Secondary pressure switch open. On the 59SC2E control, code 31 covers only the secondary (housing) pressure switch; the main switch has its own code 32. The secondary switch did not close within a minute of the gas valve closing, or opened again (31.2). After three failed tries the control locks out (31.3). If it opens during the blower delay, the blower runs its normal off delay. | Often an owner fix |
| 32 | Main pressure switch open. Code 32.1: the main (low) pressure switch stayed open more than five minutes or reopened. The inducer shuts off for 15 minutes and then the furnace tries again. | Often an owner fix |
| 33 | Main limit circuit open. Code 33.1: a limit or the flame rollout switch has opened and the burner is off. The blower runs at least four minutes; if the switch is still open after three minutes the code becomes lockout 13. | Turn it off and call a pro |
| 34 | Ignition or flame fault. The control is not seeing a steady flame: 34.1 means no flame was sensed during an ignition try, 34.2 that flame was lost before the blower came on, and 34.3 that it was lost after. Repeated failures lead to lockout 14. | Technician repair |
| 45 | Control failure. The control board has an internal fault: 45.1 a flame circuit, memory or sequence error, 45.2 a gas valve relay that will not close, 45.3 a memory chip problem. Cycle power once; if 45 returns, the board is replaced. | Technician repair |
| 46 | Brief power loss. Code 46.1: power dipped for a moment. Heating stops and starts again once the supply is steady. | Often an owner fix |
Codes that mean turn it off
These codes come from a flame, gas, venting or overheat safety. Leave the unit off and call a licensed technician rather than resetting it repeatedly:
Code by code
No code showing?
If the unit is not working and shows no code at all, start with the Furnace not working troubleshooter. It covers power, settings and supply problems that stop the control from running at all.
More error code tables
Sources
- Carrier, 59SC2E Single-Stage 35-in. Tall 4-Way Multipoise High Efficiency Condensing Gas Furnace - Installation, Start-up, Operating and Service and Maintenance Instructions (59SC2E-03SI) shareddocs.com
- Noritz, How to troubleshoot a tankless water heater noritz.com
- Carrier, Furnace not turning on (help page) carrier.com
- ENERGY STAR, Maintenance Checklist (heating and cooling) energystar.gov
- U.S. Consumer Product Safety Commission, Carbon Monoxide Information Center cpsc.gov
- Sears Home Services, Water heater problems and troubleshooting searshomeservices.com