Skip to content
WattsBack

Goodman single-stage gas furnace error codes

Goodman single-stage gas furnace code EE0: ignition lockout

The furnace tried to light three times and either never proved a flame or lost it after lighting, so the control locked out and stopped trying. The furnace will not heat until the lockout clears.

Photograph of a plain closed furnace cabinet with a metal duct in a tidy, softly lit basement
On this page
Code
EE0
Equipment
Goodman single-stage gas furnace
Models
GR9S92, GR9S96 and GD9S96; also GM9S92, GM9S96 and GC9S96
What to do
Technician repair

What code EE0 means

Goodman's Service and Troubleshooting - Single Stage Gas Furnaces and Accessories (RS6612301) lists EE0 as ignition lockout, for the GR9S92, GR9S96 and GD9S96; also GM9S92, GM9S96 and GC9S96. A three-character, seven-segment display on the furnace control board shows the code, read left to right, such as EE3 or E11. The display shows a status message instead when there is no fault.

What usually causes it

The manual points to these causes for this code, roughly in the order a technician would rule them out:

  • Gas is not reaching the burners, or the supply was interrupted.
  • The front cover pressure switch is not working, often from a drain hose or wiring problem.
  • The hot surface igniter is worn out or out of position.
  • The flame sensor is dirty or oxidized, so it cannot see the flame.
  • The flue pipe is blocked, too long or has too many elbows.
  • The inducer (the small fan that pulls exhaust through the furnace) is weak.

What you can safely check

  1. Check that gas is reaching the house. If other gas appliances (stove, dryer) also do not work, the problem is the gas supply, so call your gas utility. Do not try to light anything or adjust the gas valve yourself.
  2. Look at the vent pipes outside. High-efficiency furnaces, boilers and tankless heaters breathe through plastic pipes on an outside wall or the roof. From the ground, check that snow, ice, leaves or a nest are not blocking either opening, and clear what you can reach safely.
  3. Look at the condensate drain. Condensing equipment makes water that drains through a small hose or trap. A kinked hose, a full pump or water pooling under the unit can make it shut down. Straighten a kinked hose and empty a full pump reservoir; leave the trap itself to a technician.
  4. Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.
  5. Reset it once. Turn the unit off at its switch, wait a minute, and turn it back on, or use the reset the manual describes. One reset clears a passing glitch. If the same code comes back, stop resetting and book a technician.

When to call a technician

Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code EE0 (the manual's first suspect is gas is not reaching the burners, or the supply was interrupted). That saves a diagnostic visit from starting at zero.

Step by step for this kind of problem

The Furnace not working troubleshooter walks through the symptom question by question and ends with a clear next step.

Other Goodman single-stage gas furnace codes

The full Goodman single-stage gas furnace code table lists every code with its meaning, and explains how to read and clear them.

Sources

  1. Goodman, Service and Troubleshooting - Single Stage Gas Furnaces and Accessories (RS6612301) mobile.goodmanmfg.com
  2. Goodman, Service and Troubleshooting - Single Stage Gas Furnaces and Accessories (RS6612022R1) mobile.goodmanmfg.com
  3. Carrier, Furnace not turning on (help page) carrier.com
  4. U.S. Consumer Product Safety Commission, Carbon Monoxide Information Center cpsc.gov
  5. ENERGY STAR, Maintenance Checklist (heating and cooling) energystar.gov
  6. Noritz, How to troubleshoot a tankless water heater noritz.com