Skip to content
WattsBack

Goodman single-stage gas furnace error codes

Goodman single-stage gas furnace code EE1: pressure switch closed too early

The pressure switch reads closed before the inducer has started at the beginning of a heating call, which should never happen. The furnace will not start the burner.

Photograph of a plain closed furnace cabinet with a metal duct in a tidy, softly lit basement
On this page
Code
EE1
Equipment
Goodman single-stage gas furnace
Models
GR9S92, GR9S96 and GD9S96; also GM9S92, GM9S96 and GC9S96
What to do
Technician repair

What code EE1 means

Goodman's Service and Troubleshooting - Single Stage Gas Furnaces and Accessories (RS6612301) lists EE1 as pressure switch closed too early, for the GR9S92, GR9S96 and GD9S96; also GM9S92, GM9S96 and GC9S96. A three-character, seven-segment display on the furnace control board shows the code, read left to right, such as EE3 or E11. The display shows a status message instead when there is no fault.

What usually causes it

The manual points to these causes for this code, roughly in the order a technician would rule them out:

  • The pressure switch contacts are stuck closed.
  • A short in the pressure switch wiring.

What you can safely check

  1. Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.
  2. Reset it once. Turn the unit off at its switch, wait a minute, and turn it back on, or use the reset the manual describes. One reset clears a passing glitch. If the same code comes back, stop resetting and book a technician.

When to call a technician

Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code EE1 (the manual's first suspect is the pressure switch contacts are stuck closed). That saves a diagnostic visit from starting at zero.

Step by step for this kind of problem

The Furnace not working troubleshooter walks through the symptom question by question and ends with a clear next step.

Other Goodman single-stage gas furnace codes

The full Goodman single-stage gas furnace code table lists every code with its meaning, and explains how to read and clear them.

Sources

  1. Goodman, Service and Troubleshooting - Single Stage Gas Furnaces and Accessories (RS6612301) mobile.goodmanmfg.com
  2. Goodman, Service and Troubleshooting - Single Stage Gas Furnaces and Accessories (RS6612022R1) mobile.goodmanmfg.com
  3. Noritz, How to troubleshoot a tankless water heater noritz.com