Goodman single-stage gas furnace code EE3: high limit open

The main limit switch, a heat sensor near the heat exchanger, has opened because the furnace got too hot. The control shuts the burner off and keeps the house blower running to cool it down.

Photograph of a plain closed furnace cabinet with a metal duct in a tidy, softly lit basement
On this page
Code
EE3
Equipment
Goodman single-stage gas furnace
Models
GR9S92, GR9S96 and GD9S96; also GM9S92, GM9S96 and GC9S96
What to do
Turn it off and call a pro

What code EE3 means

Goodman's Service and Troubleshooting - Single Stage Gas Furnaces and Accessories (RS6612301) lists EE3 as high limit open, for the GR9S92, GR9S96 and GD9S96; also GM9S92, GM9S96 and GC9S96. A three-character, seven-segment display on the furnace control board shows the code, read left to right, such as EE3 or E11. The display shows a status message instead when there is no fault.

What usually causes it

The manual points to these causes for this code, roughly in the order a technician would rule them out:

  • Not enough air crossing the heat exchanger: a clogged filter or blocked or undersized ducts.
  • The blower speed is set wrong or the blower motor has failed.
  • Loose or wrongly connected wiring in the limit circuit.

What you can safely check

  1. Check the air filter. A clogged filter starves the system of air and can make a furnace overheat and shut itself down. Turn the furnace off, slide the filter out and hold it to the light; replace it if light barely passes through.
  2. Open the vents and clear the return grille. A furnace needs a free path for air: supply registers open in most rooms, and nothing (furniture, rugs, boxes) covering the large return grille. Too little airflow makes the heat exchanger run hot and trips the limit switch.
  3. Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.

When to call a technician

Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code EE3 (the manual's first suspect is not enough air crossing the heat exchanger: a clogged filter or blocked or undersized ducts). That saves a diagnostic visit from starting at zero.

Step by step for this kind of problem

The Furnace not working troubleshooter walks through the symptom question by question and ends with a clear next step.

Other Goodman single-stage gas furnace codes

The full Goodman single-stage gas furnace code table lists every code with its meaning, and explains how to read and clear them.

Sources

  1. Goodman, Service and Troubleshooting - Single Stage Gas Furnaces and Accessories (RS6612301) mobile.goodmanmfg.com
  2. Goodman, Service and Troubleshooting - Single Stage Gas Furnaces and Accessories (RS6612022R1) mobile.goodmanmfg.com
  3. Carrier, Furnace not turning on (help page) carrier.com
  4. ENERGY STAR, Maintenance Checklist (heating and cooling) energystar.gov
  5. Noritz, How to troubleshoot a tankless water heater noritz.com