Goodman single-stage gas furnace code EEL: igniter circuit fault

The control found a problem with the igniter circuit when it tried to heat the igniter, so the furnace does not light.

Photograph of a plain closed furnace cabinet with a metal duct in a tidy, softly lit basement
On this page
Code
EEL
Equipment
Goodman single-stage gas furnace
Models
GR9S92, GR9S96 and GD9S96; also GM9S92, GM9S96 and GC9S96
What to do
Technician repair

What code EEL means

Goodman's Service and Troubleshooting - Single Stage Gas Furnaces and Accessories (RS6612301) lists EEL as igniter circuit fault, for the GR9S92, GR9S96 and GD9S96; also GM9S92, GM9S96 and GC9S96. A three-character, seven-segment display on the furnace control board shows the code, read left to right, such as EE3 or E11. The display shows a status message instead when there is no fault.

What usually causes it

The manual points to these causes for this code, roughly in the order a technician would rule them out:

  • Wiring between the control board and the igniter is wrong or loose.
  • The igniter is shorted or badly connected.
  • Poor ground at the furnace.
  • The igniter relay on the control board has failed.

What you can safely check

  1. Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.
  2. Reset it once. Turn the unit off at its switch, wait a minute, and turn it back on, or use the reset the manual describes. One reset clears a passing glitch. If the same code comes back, stop resetting and book a technician.

When to call a technician

Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code EEL (the manual's first suspect is wiring between the control board and the igniter is wrong or loose). That saves a diagnostic visit from starting at zero.

Step by step for this kind of problem

The Furnace not working troubleshooter walks through the symptom question by question and ends with a clear next step.

Other Goodman single-stage gas furnace codes

The full Goodman single-stage gas furnace code table lists every code with its meaning, and explains how to read and clear them.

Sources

  1. Goodman, Service and Troubleshooting - Single Stage Gas Furnaces and Accessories (RS6612301) mobile.goodmanmfg.com
  2. Goodman, Service and Troubleshooting - Single Stage Gas Furnaces and Accessories (RS6612022R1) mobile.goodmanmfg.com
  3. Noritz, How to troubleshoot a tankless water heater noritz.com