Goodman single-stage gas furnace error codes
Goodman single-stage gas furnace code EE6: weak flame signal
The burners light and the furnace keeps heating, but the flame sensor current is lower than it should be. It is a warning that ignition lockouts may follow if nothing is done.

On this page
- Code
- EE6
- Equipment
- Goodman single-stage gas furnace
- Models
- GR9S92, GR9S96 and GD9S96; also GM9S92, GM9S96 and GC9S96
- What to do
- Technician repair
What code EE6 means
Goodman's Service and Troubleshooting - Single Stage Gas Furnaces and Accessories (RS6612301) lists EE6 as weak flame signal, for the GR9S92, GR9S96 and GD9S96; also GM9S92, GM9S96 and GC9S96. A three-character, seven-segment display on the furnace control board shows the code, read left to right, such as EE3 or E11. The display shows a status message instead when there is no fault.
What usually causes it
The manual points to these causes for this code, roughly in the order a technician would rule them out:
- The flame sensor is coated or oxidized.
- The flame sensor is not sitting properly in the burner flame.
- A lazy, weak flame from wrong gas pressure or poor combustion air, including a blocked or badly routed intake pipe.
What you can safely check
- Look at the vent pipes outside. High-efficiency furnaces, boilers and tankless heaters breathe through plastic pipes on an outside wall or the roof. From the ground, check that snow, ice, leaves or a nest are not blocking either opening, and clear what you can reach safely.
- Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.
- Reset it once. Turn the unit off at its switch, wait a minute, and turn it back on, or use the reset the manual describes. One reset clears a passing glitch. If the same code comes back, stop resetting and book a technician.
When to call a technician
Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code EE6 (the manual's first suspect is the flame sensor is coated or oxidized). That saves a diagnostic visit from starting at zero.
Step by step for this kind of problem
The Furnace not working troubleshooter walks through the symptom question by question and ends with a clear next step.
Related Goodman codes
Other Goodman single-stage gas furnace codes
The full Goodman single-stage gas furnace code table lists every code with its meaning, and explains how to read and clear them.