Goodman single-stage gas furnace error codes: what each one means

Goodman's manual for the GR9S92, GR9S96 and GD9S96; also GM9S92, GM9S96 and GC9S96 lists 23 codes. A three-character, seven-segment display on the furnace control board shows the code, read left to right, such as EE3 or E11. The display shows a status message instead when there is no fault.

Photograph of a plain closed furnace cabinet with a metal duct in a tidy, softly lit basement
On this page
Codes listed
23
Turn off and call a pro
6
Often an owner fix
0

How to read the code

The display sits on the integrated control board behind the furnace's front panels. Most fault codes start with EE followed by one character (EE0 to EE6, EEA, EEb and so on). A few start with E1 (E10 and E11), and the newest boards add Eb and EA codes for blower current and the R-32 refrigerant sensor.

The board keeps a list of recent faults. Using the three buttons next to the display, a technician scrolls with the left or right button to the fault history menu and presses the center button to read the stored codes. Holding the center button for 5 to 30 seconds wipes the list, and the display blinks three dashes to confirm.

Write down what the display shows before anyone clears the history or cuts the power. The manual lists the code next to the symptom you can see, such as the inducer running with no flame or the house blower running nonstop, and that pairing points a technician straight at the right part.

On furnaces paired with an R-32 air conditioner or heat pump, an EA code means the furnace has stopped heating on purpose and is running its fan at full speed to thin out leaked refrigerant. Gas heat stays off while the sensor reports a leak, and the furnace waits five minutes after the leak reading clears before going back to normal.

Goodman single-stage gas furnace code table

Codes with a link have their own page with causes and the checks that fit that code.

Goodman single-stage gas furnace codes, from the Service and Troubleshooting - Single Stage Gas Furnaces and Accessories (RS6612301)
CodeWhat it meansWhat to do
EE0Ignition lockout. The furnace tried to light three times and either never proved a flame or lost it after lighting, so the control locked out and stopped trying. The furnace will not heat until the lockout clears.Technician repair
EE1Pressure switch closed too early. The pressure switch reads closed before the inducer has started at the beginning of a heating call, which should never happen. The furnace will not start the burner.Technician repair
EE2Pressure switch did not close. The inducer is running but the pressure switch never closed, so the control cannot confirm that exhaust is being drawn out safely. The inducer keeps running and the burner stays off.Turn it off and call a pro
EE3High limit open. The main limit switch, a heat sensor near the heat exchanger, has opened because the furnace got too hot. The control shuts the burner off and keeps the house blower running to cool it down.Turn it off and call a pro
EE4Flame where none should be. The flame sensor reports a flame when there is no call for heat. The control runs both the inducer and the house blower and will not run a normal cycle.Turn it off and call a pro
EE5Control fuse blown. The low voltage fuse on the control board has blown, so the furnace has no 24 volt control power and does not run.Technician repair
EE6Weak flame signal. The burners light and the furnace keeps heating, but the flame sensor current is lower than it should be. It is a warning that ignition lockouts may follow if nothing is done.Technician repair
EELIgniter circuit fault. The control found a problem with the igniter circuit when it tried to heat the igniter, so the furnace does not light.Technician repair
EEAReversed polarity or grounding. The control sees the 115 volt supply wired backwards or a poor ground, and it will not run the furnace until that is corrected.Technician repair
EEbGas valve not powered. The control should be sending power to the gas valve but sees none, so the burners cannot get gas and the furnace stops.Turn it off and call a pro
EECGas valve powered when it should be off. The control sees power on the gas valve when there is no call for heat. It treats this as a serious fault and stops the furnace.Turn it off and call a pro
E10Grounding fault. The control detects a grounding problem and keeps the furnace off.Technician repair
E11Rollout switch open. A rollout switch near the burners has opened because flame came out of the burner area instead of going into the heat exchanger. The furnace shuts down and stays off.Turn it off and call a pro
EEnIgniter open circuit. The control reads no circuit through the igniter, so it cannot heat it and the furnace does not light.Technician repair
EEJInducer relay fault. The relay on the control board that runs the inducer has a fault, and the furnace will not start a heating cycle.Technician repair
EEHTwinning fault. Two furnaces set up to run together (twinned) are not working together as they should.Technician repair
EEEInternal control fault. The control board has found an internal fault in itself and the furnace does not run.Technician repair
EbLBlower drawing too little current. After the heat-on delay the main blower motor draws far less current than expected. The furnace stops and goes into a hard lockout.Technician repair
EbUBlower drawing current too early. The main blower motor draws more current than expected while only the inducer should be running. The furnace stops and goes into a hard lockout.Technician repair
EAFLost contact with refrigerant sensor. The furnace cannot talk to its R-32 refrigerant leak sensor, so it stops heating and runs only the fan as a precaution.Technician repair
EALRefrigerant leak detected. The R-32 sensor on the indoor coil has picked up leaked refrigerant. The furnace shuts off gas heat and runs the fan hard to dilute it, then returns to normal five minutes after the leak reading clears.Technician repair
EASRefrigerant sensor fault. The R-32 sensor reports a fault of its own, so the furnace stops heating and runs only the fan.Technician repair
EArLeak mitigation relay fault. The A2L relay on the furnace board, used during refrigerant leak mitigation, has a fault. Gas heat stops and only the fan runs.Technician repair

Codes that mean turn it off

These codes come from a flame, gas, venting or overheat safety. Leave the unit off and call a licensed technician rather than resetting it repeatedly:

Code by code

No code showing?

If the unit is not working and shows no code at all, start with the Furnace not working troubleshooter. It covers power, settings and supply problems that stop the control from running at all.

More error code tables

Sources

  1. Goodman, Service and Troubleshooting - Single Stage Gas Furnaces and Accessories (RS6612301) mobile.goodmanmfg.com
  2. Goodman, Service and Troubleshooting - Single Stage Gas Furnaces and Accessories (RS6612022R1) mobile.goodmanmfg.com
  3. Carrier, Furnace not turning on (help page) carrier.com
  4. U.S. Consumer Product Safety Commission, Carbon Monoxide Information Center cpsc.gov
  5. ENERGY STAR, Maintenance Checklist (heating and cooling) energystar.gov
  6. Noritz, How to troubleshoot a tankless water heater noritz.com