Goodman single-stage gas furnace error codes

Goodman single-stage gas furnace code EE2: pressure switch did not close

The inducer is running but the pressure switch never closed, so the control cannot confirm that exhaust is being drawn out safely. The inducer keeps running and the burner stays off.

Photograph of a plain closed furnace cabinet with a metal duct in a tidy, softly lit basement
On this page
Code
EE2
Equipment
Goodman single-stage gas furnace
Models
GR9S92, GR9S96 and GD9S96; also GM9S92, GM9S96 and GC9S96
What to do
Turn it off and call a pro

What code EE2 means

Goodman's Service and Troubleshooting - Single Stage Gas Furnaces and Accessories (RS6612301) lists EE2 as pressure switch did not close, for the GR9S92, GR9S96 and GD9S96; also GM9S92, GM9S96 and GC9S96. A three-character, seven-segment display on the furnace control board shows the code, read left to right, such as EE3 or E11. The display shows a status message instead when there is no fault.

What usually causes it

The manual points to these causes for this code, roughly in the order a technician would rule them out:

  • The pressure switch hose is blocked, pinched or on the wrong port.
  • The exhaust or intake pipe is blocked, or the pipe run is too long or has too many elbows.
  • The condensate drain system is blocked and water is backing up.
  • The inducer is weak.
  • The pressure switch is set wrong or its contacts are faulty.
  • Loose or wrongly connected wiring.

What you can safely check

  1. Look at the vent pipes outside. High-efficiency furnaces, boilers and tankless heaters breathe through plastic pipes on an outside wall or the roof. From the ground, check that snow, ice, leaves or a nest are not blocking either opening, and clear what you can reach safely.
  2. Look at the condensate drain. Condensing equipment makes water that drains through a small hose or trap. A kinked hose, a full pump or water pooling under the unit can make it shut down. Straighten a kinked hose and empty a full pump reservoir; leave the trap itself to a technician.
  3. Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.

When to call a technician

Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code EE2 (the manual's first suspect is the pressure switch hose is blocked, pinched or on the wrong port). That saves a diagnostic visit from starting at zero.

Step by step for this kind of problem

The Furnace not working troubleshooter walks through the symptom question by question and ends with a clear next step.

Other Goodman single-stage gas furnace codes

The full Goodman single-stage gas furnace code table lists every code with its meaning, and explains how to read and clear them.

Sources

  1. Goodman, Service and Troubleshooting - Single Stage Gas Furnaces and Accessories (RS6612301) mobile.goodmanmfg.com
  2. Goodman, Service and Troubleshooting - Single Stage Gas Furnaces and Accessories (RS6612022R1) mobile.goodmanmfg.com