Rheem tankless water heater error codes
Rheem tankless water heater code A029: condensate blockage
The sensor in the built in condensate trap found the trap full, or could not read the water level at all, so the heater stops to keep water from backing up.

On this page
- Code
- A029
- Equipment
- Rheem tankless water heater
- Models
- IKONIC RTGH-S, RUTGH-S, CRTGH-S and CRUTGH-S (S and SR, 84i, 10i, 11i)
- What to do
- Often an owner fix
What code A029 means
Rheem's Technical Training and Service Manual - Tankless Water Heaters (RTGH-S) lists A029 as condensate blockage, for the IKONIC RTGH-S, RUTGH-S, CRTGH-S and CRUTGH-S (S and SR, 84i, 10i, 11i). The code appears as text on the LCD of the front user interface: a letter and three digits, such as A011 or T113. Codes starting with T are mostly notices; A codes are errors.
What usually causes it
The manual points to these causes for this code, roughly in the order a technician would rule them out:
- The drain line from the condensate trap is blocked.
- The external condensate trap or drain is blocked.
- The condensate trap itself is faulty.
- A loose connection at the trap sensor, or a failed control board.
What you can safely check
- Look at the condensate drain. Condensing equipment makes water that drains through a small hose or trap. A kinked hose, a full pump or water pooling under the unit can make it shut down. Straighten a kinked hose and empty a full pump reservoir; leave the trap itself to a technician.
- Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.
- Reset it once. Turn the unit off at its switch, wait a minute, and turn it back on, or use the reset the manual describes. One reset clears a passing glitch. If the same code comes back, stop resetting and book a technician.
When to call a technician
Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code A029 (the manual's first suspect is the drain line from the condensate trap is blocked). That saves a diagnostic visit from starting at zero.
Step by step for this kind of problem
The Tankless water heater, no hot water troubleshooter walks through the symptom question by question and ends with a clear next step.
Related Rheem codes
Other Rheem tankless water heater codes
- A011
- A012
- A014
- A018
- A031
- A032
- A033
- A035
- A036
- A055
- A061
- A063
- A065
- A066
- A070
- A071
- A072
- A082
- A090
- A200
- A2##
- T110
- T111
- T113
- T115
- T116
The full Rheem tankless water heater code table lists every code with its meaning, and explains how to read and clear them.