Rheem tankless water heater error codes: what each one means

Rheem's manual for the IKONIC RTGH-S, RUTGH-S, CRTGH-S and CRUTGH-S (S and SR, 84i, 10i, 11i) lists 27 codes. The code appears as text on the LCD of the front user interface: a letter and three digits, such as A011 or T113. Codes starting with T are mostly notices; A codes are errors.

Photograph of a plain white wall-mounted tankless water heater with insulated pipes below it
On this page
Codes listed
27
Turn off and call a pro
4
Often an owner fix
4

How to read the code

The heater can hold up to four active alarms at once. Press SERVICE, use the arrow buttons to reach Current Alarms and press ENTER, then step through alarm 1 to 4. From the same menu, Clear Alarms removes them once the cause is fixed.

An Alarm History screen under SERVICE keeps the last six codes the heater has seen, which is useful when a code comes and goes. Note those down before anyone chooses Clear History.

A tankless heater only fires with at least 0.4 gallons per minute flowing through it, so a heater with a lit screen, no code and no hot water is often a flow problem: a faucet aerator, the inlet filter or crossed hot and cold lines. The STATUS menu shows the flow rate the heater sees.

Rheem's service manual is written for trained technicians and says homeowners should use the Use and Care manual instead. Many diagnostic steps involve live voltage and a 10,000 volt ignition circuit, and a flame rod or igniter that is removed must go back with a new gasket, so leave those steps to a pro.

Rheem tankless water heater code table

Codes with a link have their own page with causes and the checks that fit that code.

Rheem tankless water heater codes, from the Technical Training and Service Manual - Tankless Water Heaters (RTGH-S)
CodeWhat it meansWhat to do
A011Ignition failure. The heater tried to light 10 times, with a purge every third try, and the flame rod never saw a flame. It stops trying and shows A011 until the cause is found.Technician repair
A012Flame lost repeatedly. The burner lit but the flame went out during firing. Each time, the heater cuts the gas and tries again, and after 15 losses in a row it stops and shows A012.Technician repair
A014Overheat limiter tripped. One of the two overheat safeties, the limiter or the limit fuse, has opened and the heater stops firing. Rheem says this usually comes from a gas supply or venting problem.Turn it off and call a pro
A018Scale build-up in heat exchanger. Lime and scale have built up inside the heat exchanger. The heater must be drained and flushed to avoid lasting damage, then the alarm is cleared.Technician repair
A029Condensate blockage. The sensor in the built in condensate trap found the trap full, or could not read the water level at all, so the heater stops to keep water from backing up.Often an owner fix
A031Inlet thermistor fault. The sensor that reads the incoming cold water temperature is out of range, and the heater shows an error.Technician repair
A032Heat exchanger thermistor fault. The temperature sensor on the heat exchanger is reading out of range.Technician repair
A033Outlet thermistor fault. The sensor that reads hot water leaving the heater is out of range.Technician repair
A035Thermistor connection fault. One or more of the temperature sensors is poorly connected or plugged into the wrong place, so the heater shows an error.Technician repair
A036Exhaust thermistor fault. The exhaust temperature sensor is reading out of range.Technician repair
A055Gas motor fault. The small motor that sets the air valve in the venturi is not working right, so the heater cannot control its air and gas mix.Technician repair
A061Blower speed fault. After the combustion fan started, its speed signal was wrong, so the heater stops.Technician repair
A063Recirculation pump fault. The recirculation pump was running but the heater's flow sensor saw no water moving.Technician repair
A065Water volume control valve fault. The valve that limits water flow when demand exceeds what the heater can handle is not working properly.Technician repair
A066Water bypass valve fault. The motor on the water bypass valve is not working correctly.Technician repair
A070Control board processor fault. The control board's microcomputer has stopped working properly. If a power cycle does not clear it, the board is replaced.Technician repair
A071Flame seen after shutdown. The flame rod kept detecting flame for 8 seconds after the heater turned off. A flame that will not go out points at a gas valve problem, so treat this as a safety fault.Turn it off and call a pro
A072Flame seen before ignition. The flame rod reported a flame before the igniter had even started. The heater stops, because flame before the spark means gas is getting through when it should not, or the rod is faulty.Turn it off and call a pro
A082Gas chip error. The gas chip on the control board, which tells it what gas and model it is, is loose or holds the wrong data.Technician repair
A090Vent blockage. The heater sensed that its venting is blocked and stops firing. Exhaust that cannot get out is a carbon monoxide risk, so leave it off until the vent is checked.Turn it off and call a pro
A200Display communication failure. The user interface on the front is not talking to the control board.Technician repair
A2##Fault on another manifolded heater. In a group of linked heaters, the manager unit shows A2 plus the instance number of a heater that has its own error; A205 means unit 5. Read the code on that unit.Technician repair
T110WiFi chip error. The user interface has lost contact with its WiFi chip. Resetting WiFi is the first step; if it returns, the interface is replaced.Technician repair
T111Service reminder. The service alert interval has been reached and the heater needs draining and flushing. It is a warning at first, but the heater will eventually shut down to protect itself.Often an owner fix
T113Flow too low to fire. Water is moving through the heater at less than 0.4 gallons per minute, which is below the minimum it needs, so the burner will not come on.Often an owner fix
T115Pump schedule not received. A recirculation schedule is set, but the interface has not received the time to run the pump.Often an owner fix
T116Manifold unit fault. In a manifold, some heaters cannot communicate with the manager unit.Technician repair

Codes that mean turn it off

These codes come from a flame, gas, venting or overheat safety. Leave the unit off and call a licensed technician rather than resetting it repeatedly:

Code by code

No code showing?

If the unit is not working and shows no code at all, start with the Tankless water heater, no hot water troubleshooter. It covers power, settings and supply problems that stop the control from running at all.

More error code tables

Sources

  1. Rheem, Technical Training and Service Manual - Tankless Water Heaters (RTGH-S) res.cloudinary.com
  2. Carrier, Furnace not turning on (help page) carrier.com
  3. U.S. Consumer Product Safety Commission, Carbon Monoxide Information Center cpsc.gov
  4. Noritz, How to troubleshoot a tankless water heater noritz.com
  5. ENERGY STAR, Maintenance Checklist (heating and cooling) energystar.gov