Rheem tankless water heater error codes
Rheem tankless water heater code A071: flame seen after shutdown
The flame rod kept detecting flame for 8 seconds after the heater turned off. A flame that will not go out points at a gas valve problem, so treat this as a safety fault.

On this page
- Code
- A071
- Equipment
- Rheem tankless water heater
- Models
- IKONIC RTGH-S, RUTGH-S, CRTGH-S and CRUTGH-S (S and SR, 84i, 10i, 11i)
- What to do
- Turn it off and call a pro
What code A071 means
Rheem's Technical Training and Service Manual - Tankless Water Heaters (RTGH-S) lists A071 as flame seen after shutdown, for the IKONIC RTGH-S, RUTGH-S, CRTGH-S and CRUTGH-S (S and SR, 84i, 10i, 11i). The code appears as text on the LCD of the front user interface: a letter and three digits, such as A011 or T113. Codes starting with T are mostly notices; A codes are errors.
What usually causes it
The manual points to these causes for this code, roughly in the order a technician would rule them out:
- The gas-air ratio valve is not closing, so flame stays visible after shutdown.
- The flame rod is dirty or faulty and reports a flame that is not there.
- The control board has failed.
- A loose connection or debris that clears once the plugs are reseated.
What you can safely check
- Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.
When to call a technician
Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code A071 (the manual's first suspect is the gas-air ratio valve is not closing, so flame stays visible after shutdown). That saves a diagnostic visit from starting at zero.
Step by step for this kind of problem
The Tankless water heater, no hot water troubleshooter walks through the symptom question by question and ends with a clear next step.
Related Rheem codes
Other Rheem tankless water heater codes
- A011
- A012
- A014
- A018
- A029
- A031
- A032
- A033
- A035
- A036
- A055
- A061
- A063
- A065
- A066
- A070
- A072
- A082
- A090
- A200
- A2##
- T110
- T111
- T113
- T115
- T116
The full Rheem tankless water heater code table lists every code with its meaning, and explains how to read and clear them.