Skip to content
WattsBack

A.O. Smith heat pump water heater error codes

A.O. Smith heat pump water heater code Fan Connect Fault: heat pump fan circuit open

The circuit to the fan that pulls room air over the evaporator is open. Without that fan the heat pump cannot collect heat from the air.

Photograph of a plain white tank water heater with copper pipes in a tidy utility closet
On this page
Code
Fan Connect Fault
Equipment
A.O. Smith heat pump water heater
Models
PHPT-60 and PHPT-80 hybrid electric heat pump water heaters
What to do
Technician repair

What code Fan Connect Fault means

A.O. Smith's Service Handbook - Residential Hybrid Electric Heat Pump Water Heater, incl. fault codes (321547-000) lists Fan Connect Fault as heat pump fan circuit open, for the PHPT-60 and PHPT-80 hybrid electric heat pump water heaters. Faults show as a text message on the touch display on the front of the heater. The exact fault name is kept in a maintenance screen as codes E01 to E04, newest first.

What usually causes it

The manual points to these causes for this code, roughly in the order a technician would rule them out:

  • The fan plug on the control board is not seated, or a wire is damaged.
  • The fan motor's internal protector has opened or the motor has failed.
  • The control board is faulty.

What you can safely check

  1. Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.
  2. Reset it once. Turn the unit off at its switch, wait a minute, and turn it back on, or use the reset the manual describes. One reset clears a passing glitch. If the same code comes back, stop resetting and book a technician.

When to call a technician

Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code Fan Connect Fault (the manual's first suspect is the fan plug on the control board is not seated, or a wire is damaged). That saves a diagnostic visit from starting at zero.

Step by step for this kind of problem

The Water heater, no hot water troubleshooter walks through the symptom question by question and ends with a clear next step.

Other A.O. Smith heat pump water heater codes

The full A.O. Smith heat pump water heater code table lists every code with its meaning, and explains how to read and clear them.

Sources

  1. A.O. Smith, Service Handbook - Residential Hybrid Electric Heat Pump Water Heater, incl. fault codes (321547-000) assets.aosmith.com
  2. Noritz, How to troubleshoot a tankless water heater noritz.com