A.O. Smith heat pump water heater code Heat Pump Connect Fault: compressor circuit open

The control sees the circuit to the heat pump compressor as open, so the heat pump cannot run. Water heating falls back on the electric elements until the fault is cleared.

Photograph of a plain white tank water heater with copper pipes in a tidy utility closet
On this page
Code
Heat Pump Connect Fault
Equipment
A.O. Smith heat pump water heater
Models
PHPT-60 and PHPT-80 hybrid electric heat pump water heaters
What to do
Technician repair

What code Heat Pump Connect Fault means

A.O. Smith's Service Handbook - Residential Hybrid Electric Heat Pump Water Heater, incl. fault codes (321547-000) lists Heat Pump Connect Fault as compressor circuit open, for the PHPT-60 and PHPT-80 hybrid electric heat pump water heaters. Faults show as a text message on the touch display on the front of the heater. The exact fault name is kept in a maintenance screen as codes E01 to E04, newest first.

What usually causes it

The manual points to these causes for this code, roughly in the order a technician would rule them out:

  • A loose plug or damaged wire at the compressor, control board, run capacitor or compressor relay.
  • The compressor's thermal protector has opened; it closes again once the compressor cools.
  • The run capacitor has failed.
  • The control board is faulty.
  • The compressor itself has failed.

What you can safely check

  1. Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.
  2. Reset it once. Turn the unit off at its switch, wait a minute, and turn it back on, or use the reset the manual describes. One reset clears a passing glitch. If the same code comes back, stop resetting and book a technician.

When to call a technician

Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code Heat Pump Connect Fault (the manual's first suspect is a loose plug or damaged wire at the compressor, control board, run capacitor or compressor relay). That saves a diagnostic visit from starting at zero.

Step by step for this kind of problem

The Water heater, no hot water troubleshooter walks through the symptom question by question and ends with a clear next step.

Other A.O. Smith heat pump water heater codes

The full A.O. Smith heat pump water heater code table lists every code with its meaning, and explains how to read and clear them.

Sources

  1. A.O. Smith, Service Handbook - Residential Hybrid Electric Heat Pump Water Heater, incl. fault codes (321547-000) assets.aosmith.com
  2. Noritz, How to troubleshoot a tankless water heater noritz.com