A.O. Smith heat pump water heater error codes
A.O. Smith heat pump water heater code High Temperature Lock Out: overheat cutoff tripped
The energy cut off, a high limit switch above the upper element, tripped when the tank reached about 190 degrees F. It cuts power to the elements and the compressor and stays off until it is reset by hand.

On this page
- Code
- High Temperature Lock Out
- Equipment
- A.O. Smith heat pump water heater
- Models
- PHPT-60 and PHPT-80 hybrid electric heat pump water heaters
- What to do
- Turn it off and call a pro
What code High Temperature Lock Out means
A.O. Smith's Service Handbook - Residential Hybrid Electric Heat Pump Water Heater, incl. fault codes (321547-000) lists High Temperature Lock Out as overheat cutoff tripped, for the PHPT-60 and PHPT-80 hybrid electric heat pump water heaters. Faults show as a text message on the touch display on the front of the heater. The exact fault name is kept in a maintenance screen as codes E01 to E04, newest first.
What usually causes it
The manual points to these causes for this code, roughly in the order a technician would rule them out:
- The control board is not shutting off the element or heat pump when it should.
- Wiring between the energy cut off and the control board is loose or damaged.
- The upper tank temperature sensor is faulty.
- The energy cut off switch itself is faulty.
What you can safely check
- Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.
When to call a technician
Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code High Temperature Lock Out (the manual's first suspect is the control board is not shutting off the element or heat pump when it should). That saves a diagnostic visit from starting at zero.
Step by step for this kind of problem
The Water heater, no hot water troubleshooter walks through the symptom question by question and ends with a clear next step.
Related A.O. Smith codes
Other A.O. Smith heat pump water heater codes
- Upper Element Connect Fault
- Lower Element Connect Fault
- Heat Pump Connect Fault
- Fan Connect Fault
- Ambient Temperature Sensor Short or Open or Ad Error
- Upper Temperature Sensor Short or Open or Ad Error
- Lower Temperature Sensor Short or Open or Ad Error
- Discharge Temperature Sensor Short or Open or Ad Error
- Coil Temperature Sensor Short or Open or Ad Error
- Low Water Level Alarm
- Heat Pump Low Pressure Fault
- Heat Pump High Pressure Fault
- Heat Pump High Temperature Fault
- Main Control Board Crystal Fault
- Main Control Board RAM Fault
- Main Control Board ROM Fault
- Main Control Board EEPROM Fault
- Main Control Board State Fault
- Low Supply Voltage Fault (Low input voltage)
- High Supply Voltage Fault
- Low Supply Voltage Fault (Very low input voltage)
- Condensate Drain Alarm
- Power Anode Over Current
- Power Anode Max Current at Min PWM
- Power Anode Offset Current
- Power Anode Drive Voltage LT Tank Voltage
- Power Anode ADC Error
- Power Anode No Tank Voltage
- Power Anode No Current Sense
- Power Anode Wrong Voltage Feedback
The full A.O. Smith heat pump water heater code table lists every code with its meaning, and explains how to read and clear them.