Skip to content
WattsBack

A.O. Smith heat pump water heater error codes

A.O. Smith heat pump water heater code Upper Element Connect Fault: upper heating element circuit open

The control found the circuit to the upper heating element open, so that element cannot heat. Since the upper element heats the top of the tank first, losing it can leave you with no hot water.

Photograph of a plain white tank water heater with copper pipes in a tidy utility closet
On this page
Code
Upper Element Connect Fault
Equipment
A.O. Smith heat pump water heater
Models
PHPT-60 and PHPT-80 hybrid electric heat pump water heaters
What to do
Technician repair

What code Upper Element Connect Fault means

A.O. Smith's Service Handbook - Residential Hybrid Electric Heat Pump Water Heater, incl. fault codes (321547-000) lists Upper Element Connect Fault as upper heating element circuit open, for the PHPT-60 and PHPT-80 hybrid electric heat pump water heaters. Faults show as a text message on the touch display on the front of the heater. The exact fault name is kept in a maintenance screen as codes E01 to E04, newest first.

What usually causes it

The manual points to these causes for this code, roughly in the order a technician would rule them out:

  • A loose connection or a damaged wire at the upper element.
  • The upper element itself has burned out.
  • The control board is faulty, if the wiring and element test good.

What you can safely check

  1. Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.
  2. Reset it once. Turn the unit off at its switch, wait a minute, and turn it back on, or use the reset the manual describes. One reset clears a passing glitch. If the same code comes back, stop resetting and book a technician.

When to call a technician

Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code Upper Element Connect Fault (the manual's first suspect is a loose connection or a damaged wire at the upper element). That saves a diagnostic visit from starting at zero.

Step by step for this kind of problem

The Water heater, no hot water troubleshooter walks through the symptom question by question and ends with a clear next step.

Other A.O. Smith heat pump water heater codes

The full A.O. Smith heat pump water heater code table lists every code with its meaning, and explains how to read and clear them.

Sources

  1. A.O. Smith, Service Handbook - Residential Hybrid Electric Heat Pump Water Heater, incl. fault codes (321547-000) assets.aosmith.com
  2. Noritz, How to troubleshoot a tankless water heater noritz.com