A.O. Smith heat pump water heater error codes
A.O. Smith heat pump water heater code Low Water Level Alarm: tank not full (dry fire protection)
During its start up check the control found the heating elements may not be covered by water. The heater will not run while the alarm is active, which protects the elements from burning out.

On this page
- Code
- Low Water Level Alarm
- Equipment
- A.O. Smith heat pump water heater
- Models
- PHPT-60 and PHPT-80 hybrid electric heat pump water heaters
- What to do
- Often an owner fix
What code Low Water Level Alarm means
A.O. Smith's Service Handbook - Residential Hybrid Electric Heat Pump Water Heater, incl. fault codes (321547-000) lists Low Water Level Alarm as tank not full (dry fire protection), for the PHPT-60 and PHPT-80 hybrid electric heat pump water heaters. Faults show as a text message on the touch display on the front of the heater. The exact fault name is kept in a maintenance screen as codes E01 to E04, newest first.
What usually causes it
The manual points to these causes for this code, roughly in the order a technician would rule them out:
- The tank was not completely filled before the power was turned on.
- Air is trapped in the top of the tank and was not purged through the hot taps.
What you can safely check
- Check the water supply valves. Make sure the cold water valve to the heater is fully open and that the home has water pressure at other taps. A partly closed valve starves the heater of water.
- Reset it once. Turn the unit off at its switch, wait a minute, and turn it back on, or use the reset the manual describes. One reset clears a passing glitch. If the same code comes back, stop resetting and book a technician.
- Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.
When to call a technician
Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code Low Water Level Alarm (the manual's first suspect is the tank was not completely filled before the power was turned on). That saves a diagnostic visit from starting at zero.
Step by step for this kind of problem
The Water heater, no hot water troubleshooter walks through the symptom question by question and ends with a clear next step.
Related A.O. Smith codes
Other A.O. Smith heat pump water heater codes
- Upper Element Connect Fault
- Lower Element Connect Fault
- Heat Pump Connect Fault
- Fan Connect Fault
- Ambient Temperature Sensor Short or Open or Ad Error
- Upper Temperature Sensor Short or Open or Ad Error
- Lower Temperature Sensor Short or Open or Ad Error
- Discharge Temperature Sensor Short or Open or Ad Error
- Coil Temperature Sensor Short or Open or Ad Error
- Heat Pump Low Pressure Fault
- Heat Pump High Pressure Fault
- Heat Pump High Temperature Fault
- Main Control Board Crystal Fault
- Main Control Board RAM Fault
- Main Control Board ROM Fault
- Main Control Board EEPROM Fault
- Main Control Board State Fault
- Low Supply Voltage Fault (Low input voltage)
- High Supply Voltage Fault
- Low Supply Voltage Fault (Very low input voltage)
- High Temperature Lock Out
- Condensate Drain Alarm
- Power Anode Over Current
- Power Anode Max Current at Min PWM
- Power Anode Offset Current
- Power Anode Drive Voltage LT Tank Voltage
- Power Anode ADC Error
- Power Anode No Tank Voltage
- Power Anode No Current Sense
- Power Anode Wrong Voltage Feedback
The full A.O. Smith heat pump water heater code table lists every code with its meaning, and explains how to read and clear them.