A.O. Smith tankless water heater error codes: what each one means

A.O. Smith's manual for the 910 and 910 ASME (T-M50 and T-M50 ASME) tankless water heaters lists 21 codes. A three digit number appears on the small seven segment LED on the heater's main computer board, one digit at a time, and on the optional remote controller as a whole number.

Photograph of a plain white wall-mounted tankless water heater with insulated pipes below it
On this page
Codes listed
21
Turn off and call a pro
5
Often an owner fix
0

How to read the code

The 910 has two combustion sections, right and left. The seven segment LED on the central computer board spells out the code one digit at a time and repeats it, so 321 shows as 3, then 2, then 1. Next to it, the top red lamp flashes when the fault is in the right section and the middle red lamp flashes when it is in the left section.

With the optional TM-RE30 remote controller, the whole three digit code shows on its screen at once, which is easier to read than the board. If the remote's screen is blank, press its power button: the display turns itself off after five minutes without use.

Linked systems read differently. In an Easy-Link setup, the parent unit's LED shows five digits, the three digit code followed by the number of the unit at fault, while the remote shows the unit number followed by the first two digits of the code. The unit with the fault also shows its own code the usual way.

Not every oddity is a fault. The fan keeps spinning for about 35 seconds after the tap closes, which is normal. The heater needs at least 0.5 gallons per minute through it to light, and freeze protection inside the unit only works while it has power.

A.O. Smith tankless water heater code table

Codes with a link have their own page with causes and the checks that fit that code.

A.O. Smith tankless water heater codes, from the 910 / 910 ASME On-Demand Water Heater Installation Manual and Owner's Guide, incl. error codes
CodeWhat it meansWhat to do
031Wrong dip switch setting. The dip switches on the computer board are set incorrectly for this unit or its linked system.Technician repair
101Combustion warning. An early warning tied to code 991: the control is seeing combustion that is drifting toward the imperfect combustion fault.Turn it off and call a pro
111Ignition failure. The burner did not light when hot water was called for.Technician repair
121Flame lost. The burner lit, then the control lost the flame during use.Technician repair
311Outlet temperature sensor fault. The thermistor that reads the hot water leaving the heater has failed.Technician repair
321Inlet temperature sensor fault. The thermistor that reads the incoming cold water has failed.Technician repair
331Mixing temperature sensor fault. The thermistor that reads the mixed water temperature has failed.Technician repair
391Air fuel ratio rod fault. The rod the control uses to judge the air and fuel mix in the flame has failed.Technician repair
441Flow sensor fault. The sensor that measures water flow through the heater has failed, so the heater cannot tell when to fire.Technician repair
510Main gas valve fault. The control found the main gas valve acting abnormally.Turn it off and call a pro
551Gas solenoid valve fault. The control found one of the gas solenoid valves acting abnormally.Turn it off and call a pro
611Fan motor fault. The combustion fan motor inside the heater is not working as it should.Technician repair
631External pump fault. An external pump connected to the heater, such as one in a recirculation or heating loop, is acting abnormally.Technician repair
651Water control valve fault (flow adjustment). The water control valve is not handling its flow adjustment job, which limits how much water passes through.Technician repair
661Water control valve fault (bypass). The water control valve is not handling its bypass job, which blends cold water into the outlet.Technician repair
681External fan motor fault. An external fan motor connected to the heater is acting abnormally.Technician repair
701Computer board fault. The heater's computer board has a fault.Technician repair
721False flame. The control detected a flame at a time when the burner should be off.Turn it off and call a pro
741Remote controller communication fault. The heater and the remote controller are not communicating properly.Technician repair
761Linked system communication fault. Units in an Easy-Link or multi-unit system are not communicating properly with each other.Technician repair
991Imperfect combustion. The control found the burner is not burning cleanly, a combustion fault that needs a technician before more use.Turn it off and call a pro

Codes that mean turn it off

These codes come from a flame, gas, venting or overheat safety. Leave the unit off and call a licensed technician rather than resetting it repeatedly:

No code showing?

If the unit is not working and shows no code at all, start with the Tankless water heater, no hot water troubleshooter. It covers power, settings and supply problems that stop the control from running at all.

More error code tables

Sources

  1. A.O. Smith, 910 / 910 ASME On-Demand Water Heater Installation Manual and Owner's Guide, incl. error codes assets.hotwater.com
  2. Noritz, How to troubleshoot a tankless water heater noritz.com
  3. Carrier, Furnace not turning on (help page) carrier.com
  4. U.S. Consumer Product Safety Commission, Carbon Monoxide Information Center cpsc.gov