Rinnai tankless water heater error codes: what each one means
Rinnai's manual for the SENSEI and non-SENSEI tankless: RU, RUR, RUC, RE, RX, CX, RL, V series (incl. V53De), RH180 lists 45 codes. The code flashes as two digits or two letters on the temperature controller or the heater's front display, for example 11, 12 or LC. It stops flashing once the problem is fixed and the heater is supplying hot water again.

On this page
- Codes listed
- 45
- Turn off and call a pro
- 14
- Often an owner fix
- 9
How to read the code
Rinnai heaters show codes on the temperature controller, either the one on the front of the unit or a wall controller. In normal use the V53De front display shows two dashes when it has power but no demand, and On while it is heating water. A flashing number or pair of letters is a diagnostic code.
You can call up the recent history. On the RX and CX controller, switch the heater off, then hold On/Off for two seconds and press the Up arrow with it; the last nine codes flash one after another, and the same press takes you back out. In that history a 00 stands in for LC, and FF is a marker a service tech enters after doing maintenance.
Not every code stops the heater. Codes 41 and 51 point at a sensor but let it keep running, with the display switching between the code and the set temperature. LC codes ask for a flush; pressing On/Off five times buys about 70 hours of use before it locks out again. Codes 57 and 58 need the fault fixed and then a power off and on, which Rinnai calls a hard reset.
Rinnai's troubleshooting guide is written for trained professionals, and the V53De manual tells owners to call a licensed professional for any fix that involves gas or electricity. The temperature controller does not cut power to the heater; unplugging it or switching off its breaker does. Rinnai also warns never to adjust the internal gas valve.
Rinnai tankless water heater code table
Codes with a link have their own page with causes and the checks that fit that code.
| Code | What it means | What to do |
|---|---|---|
| SEt | Initial settings not confirmed. On SENSEI RX and CX models, SEt appears on first power-up until a professional confirms or changes the gas type and indoor or outdoor setting. | Often an owner fix |
| 02 | Burner will not fire during freeze protection. On non-SENSEI models, the heater tried to fire its burner to protect itself from freezing but could not get it lit. Without that burner the unit relies on its electric freeze protection alone. | Technician repair |
| 03 | Power cut during bath fill. Power was interrupted while the bath fill feature was running. Pressing On/Off twice clears it; if it keeps coming back after three resets, the circuit board is at fault. | Often an owner fix |
| 05 | Bypass valve fault. The bypass flow control device, a motorized valve that blends some cold water into the outgoing hot water, is not working as the board expects. On the RH180 hybrid the same number points at airflow problems. | Technician repair |
| 07 | Circulation flow too low (RH180). On the RH180 hybrid tank-tankless heater, water is circulating through the unit at less than 2.1 gallons per minute, too little for it to work properly, so it flags the low flow. | Often an owner fix |
| 10 | Air supply or exhaust blocked. The heater cannot move enough combustion air in or exhaust out, or on condensing SENSEI models the condensate trap has filled up. It shuts down rather than run with blocked venting. | Turn it off and call a pro |
| 11 | No ignition. Hot water was called for, but the burner never lit. The heater stops trying and shows the code, so no hot water is made until the cause is fixed. | Technician repair |
| 12 | Flame failure. The burner lit but the flame was lost, or the flame rod stopped sensing it. The heater shuts the gas off and shows the code instead of keeping on trying. | Technician repair |
| 13 | Combustion problem (RH180). On the RH180 hybrid, the control found the burner is not burning cleanly and shut it down. The manual's checks center on the venting and on fresh air for combustion. | Turn it off and call a pro |
| 14 | Overheat safety tripped. An overheat switch or thermal fuse on the heat exchanger has opened because it got too hot. Rinnai says to take this code seriously; the switch resets once it cools, but it trips again if the cause stays. | Turn it off and call a pro |
| 15 | Venturi control fault. On SENSEI models, the part of the gas valve that sets the mix of gas and air (the venturi control) is not responding as expected, so the heater stops. | Technician repair |
| 16 | Outgoing water too hot. The water leaving the heater passed 203 °F (95 °C), so the heater did a safety shutdown. The V53De manual describes it as an over temperature warning because the unit is too hot. | Turn it off and call a pro |
| 17 | Venturi blocked. On SENSEI models, debris is blocking the venturi where gas and air mix ahead of the fan. After cleaning, a technician clears the code with buttons on the circuit board. | Technician repair |
| 18 | Gas valve at its adjustment limit. On SENSEI RX and CX models, the self-adjusting gas valve has pushed the gas and air mix as far rich or lean as it is allowed to go, which should not happen in normal running. | Turn it off and call a pro |
| 19 | Electrical grounding fault. If it shows as soon as water starts flowing, a component in the heater's DC circuit, such as a wiring harness or a water valve, has an electrical short. | Technician repair |
| 21 | Data transfer error. On SENSEI models, settings did not carry over correctly after a circuit board was replaced, and the parameters need to be entered again. | Technician repair |
| 22 | Gas valve adjustment fault. On SENSEI RX and CX models, the gas valve's setup is off: either its reed switch is out of place or its stored parameters are wrong. | Turn it off and call a pro |
| 25 | Condensate pump or drain problem. Condensate backed up far enough to trip the float safety switch, or the add-on condensate pump stopped working. The heater shuts down to avoid spilling water. | Often an owner fix |
| 30 | Flammable vapor sensor (RH180). On the RH180, the flammable vapor sensor has tripped or failed. Rinnai says to leave the room until it is declared safe and all vapors are gone. | Turn it off and call a pro |
| 31 | Burner thermocouple out of range. On non-SENSEI and RH180 models, the burner thermocouple reading is too high, which suggests over-firing, or too low, which suggests weak gas supply. | Technician repair |
| 32 | Outlet water sensor fault. The thermistor that reads the temperature of water leaving the heater is giving a bad reading. | Technician repair |
| 33 | Heat exchanger sensor fault. The thermistor on the heat exchanger outlet is reading out of range, so the control cannot trust that temperature. | Technician repair |
| 34 | Combustion air or lime sensor fault. On non-SENSEI models this is the combustion air temperature sensor; on SENSEI RX and CX models it is the sensor that watches for lime (scale) buildup. Either one is reading wrong. | Technician repair |
| 35 | Tank sensor fault (RH180). On the RH180 hybrid, the temperature sensor in the small storage tank is reading out of range. | Technician repair |
| 38 | Exhaust sensor fault (CO sensor on RH180). The exhaust gas temperature sensor is reading wrong, so the heater stops. On the RH180 this code comes from the carbon monoxide sensor, which points at poor combustion or venting. | Turn it off and call a pro |
| 41 | Outdoor air sensor fault. The outside air or freeze protection sensor is open or disconnected. Depending on the model the heater either keeps running with the code alternating on the display or will not fire. | Technician repair |
| 51 | Inlet water sensor fault. The sensor that reads incoming cold water temperature is open or disconnected. The heater keeps working and alternates the code with the set temperature. | Technician repair |
| 52 | Gas valve signal fault. The control found a problem with the gas valve or its modulating solenoid, the coil that varies gas flow to match demand. The heater stops until a technician repairs or replaces the valve. | Turn it off and call a pro |
| 54 | Exhaust too hot. Exhaust gas went over 163 °F. The heater first turns its burner down, and if the exhaust is still too hot after two minutes it shuts down and shows the code. | Turn it off and call a pro |
| 57 | Burner overheat switch open. On non-SENSEI models, one of two heat switches on the back of the burner has opened because the burner got too hot. The code shows even when the heater is idle and needs a hard reset after the fault is fixed. | Turn it off and call a pro |
| 58 | Secondary heat exchanger overheat switch open. On non-SENSEI models, a heat switch on the secondary heat exchanger has opened. Rinnai says this points to scale inside that heat exchanger, which must be flushed out before it causes damage. | Turn it off and call a pro |
| 61 | Combustion fan motor fault. The fan that feeds air to the burner is not turning, or not turning at the speed the board commands, so the heater cannot fire safely. | Technician repair |
| 63 | Recirculation flow too low. The heater's recirculation system is not getting enough water moving through its loop, so it flags low flow. Air in the pipes, closed valves and settings that do not match the plumbing are the main reasons the guide gives. | Often an owner fix |
| 65 | Water flow control fault. The water flow control valve, which limits flow so the heater can keep up, has a fault; during bath fill it means the valve did not close. The guide says to stop the water flow and the bath fill right away. | Technician repair |
| 66 | Bypass servo fault. On SENSEI RX and CX models, the bypass flow servo is reading out of range, so the heater cannot control how much cold water it blends in. | Technician repair |
| 70 | Circuit board fault. The heater's main PC board has a fault. After checking settings and connections, the fix is a new board with the settings moved over. | Technician repair |
| 71 | Gas solenoid valve fault. The control found a fault in the circuit for the gas solenoid valves, the electric valves that open to let gas reach the burner. The heater will not fire until the cause is fixed. | Turn it off and call a pro |
| 72 | Flame rod fault. The flame rod, the probe that proves the burner is lit, is not giving a good signal, so the control cannot confirm the flame. | Technician repair |
| 73 | Burner thermocouple fault. On non-SENSEI models, the thermocouple that watches burner temperature has a fault in its circuit. | Technician repair |
| 79 | Water leak detected. On non-SENSEI models, the leak sensor in the bottom of the cabinet has found water, so the heater stops. | Technician repair |
| FE | Flammable vapors detected (RH180). On the RH180, the sensor detected flammable vapors around the heater. Leave the area until it is declared safe; a qualified technician then checks the sensor. | Turn it off and call a pro |
| FF | Maintenance marker. FF is not a fault. A service provider enters it into the code history to show that maintenance was done. | Often an owner fix |
| SE | Fault on a cascaded heater. On SENSEI commercial and CX systems linked together, the main heater's display alternates SE with the set temperature when one of the other heaters has a code. | Often an owner fix |
| SS | Service soon reminder. SS is a timed reminder set at installation that the heater is due for service, mainly a heat exchanger flush. | Often an owner fix |
| LC | Scale buildup in the heat exchanger. LC, or LC0 to LC9, means mineral scale is clogging the heat exchanger, which should be flushed out before it is damaged. On newer models the code locks the heater out; a temporary reset gives about 70 hours of use at a time. | Often an owner fix |
Codes that mean turn it off
These codes come from a flame, gas, venting or overheat safety. Leave the unit off and call a licensed technician rather than resetting it repeatedly:
Code by code
No code showing?
If the unit is not working and shows no code at all, start with the Tankless water heater, no hot water troubleshooter. It covers power, settings and supply problems that stop the control from running at all.
More error code tables
Sources
- Rinnai, Troubleshooting Tankless Water Heater Diagnostic Codes (100000652) media.rinnai.us
- Rinnai, V53De Installation and Operation Manual, incl. diagnostic codes (100000561) media.rinnai.us
- Carrier, Furnace not turning on (help page) carrier.com
- U.S. Consumer Product Safety Commission, Carbon Monoxide Information Center cpsc.gov
- Noritz, How to troubleshoot a tankless water heater noritz.com
- ENERGY STAR, Maintenance Checklist (heating and cooling) energystar.gov