Navien combi boiler error codes: what each one means

Navien's manual for the NCB-E condensing combi boilers: NCB-150E, 180E, 210E, 240E lists 26 codes. The combi boiler shows an E and three digits on its front display while the error icon lights. In normal running the same display instead alternates between supply water temperature and system pressure.

Photograph of a plain white wall-mounted tankless water heater with insulated pipes below it
On this page
Codes listed
26
Turn off and call a pro
4
Often an owner fix
1

How to read the code

The NCB-E front display normally switches every five seconds between the heating supply temperature and the system water pressure in psi. When the boiler finds a fault, the error icon lights and a three digit E code takes their place.

To clear a code, use the Reset button on the panel face. After a power cut the boiler restarts on its own and keeps your settings, so a blackout alone does not need a reset. If the code returns after a reset, the manual says to call a licensed technician or Navien support.

Press the Mode button three times and INFO appears. The plus and minus buttons then step through readings such as supply and return temperature, hot water flow, outdoor temperature and the heating water pressure. Press Reset to leave this mode. These numbers help a technician on the phone.

Because one NCB-E heats both the house and your tap water, remember that space heating pauses while it is making hot water; that is normal, not a fault. Codes from E205 to E353 and E777 concern the heating loop, its water pressure and its fill valve, while E407 and E421 concern the tap water side.

Navien combi boiler code table

Codes with a link have their own page with causes and the checks that fit that code.

Navien combi boiler codes, from the User's Information Manual - NCB-E Condensing Combi-Boilers
CodeWhat it meansWhat to do
E003Combi burner failed to light. The NCB-E could not get its burner lit for heating or hot water and stops trying until reset.Technician repair
E004Combi false flame. The combi boiler sensed a flame when none should exist and will not fire.Turn it off and call a pro
E012Combi lost its flame. The NCB-E burner lit and then the flame signal dropped out, whether it was heating the house or tap water. The boiler shuts the gas and waits for a reset.Technician repair
E016Combi heat exchanger overheat. The NCB-E heat exchanger passed its safe temperature and the burner stopped; Navien advises leaving it off for 30 minutes or more before restarting.Turn it off and call a pro
E030Combi exhaust temperature fault. Flue gas leaving the combi boiler is hotter or otherwise outside what the control expects.Turn it off and call a pro
E046Combi limit control fault. The combi boiler's overheat limit has tripped or reads abnormally.Turn it off and call a pro
E047Combi exhaust thermostat fault. The thermostat watching the combi boiler's flue is not working normally.Technician repair
E060Combi venturi fault. The two-stage gas and air mixer in the combi boiler is not working as designed.Technician repair
E109Combi fan motor fault. The combi boiler's combustion fan is not running the way the control expects.Technician repair
E110Combi air pressure fault. The NCB-E sensed air pressure in its combustion path outside the normal band, so it stops heating the house and the taps. Air is not moving freely in or out of the boiler, and a vent pipe that is broken or has come apart can let exhaust into the home, so in that case keep the boiler off and call a technician.Often an owner fix
E205Heating supply sensor fault. The sensor reading water going out to the radiators or floor loops shows an open or short circuit.Technician repair
E218Heating return sensor fault. The sensor on water coming back from the heating loop shows an open or short circuit.Technician repair
E351Auto fill valve fault. The automatic feeder that tops up the heating loop with make-up water is not working properly.Technician repair
E352Heating water pressure too high. Pressure in the combi boiler's heating loop has risen above its normal range.Technician repair
E353Pressure sensor fault. The sensor that reads heating loop pressure is not giving a valid signal.Technician repair
E407Tap water outlet sensor fault. The sensor on the domestic hot water outlet of the combi reads open or shorted.Technician repair
E421Tap water inlet sensor fault. The sensor on the cold water coming into the combi reads open or shorted.Technician repair
E439Hot water flow sensor fault. The combi's tap water flow sensor gave a bad reading; Navien's first step is a reset from the front panel.Technician repair
E515Combi control board fault. The combi boiler's circuit board found a fault in itself.Technician repair
E517Combi DIP switch fault. The combi boiler's setup switches are in a setting it rejects.Technician repair
E594Combi memory fault. The chip storing the combi boiler's settings failed its check.Technician repair
E615Combi input and memory fault. The combi control found a problem with its inputs or memory.Technician repair
E736Combi cascade fault. A combi boiler linked with others in a cascade has lost communication with them.Technician repair
E740Outdoor reset sensor fault. With outdoor reset turned on, which raises or lowers heating temperature with the weather, the outdoor sensor is not reading properly.Technician repair
E777Low water cutoff fault. The low water cutoff, a safety that stops the burner if the heating loop runs short of water, has acted or is reading wrong.Technician repair
E782Combi panel link fault. The combi boiler's main board and front panel have lost communication.Technician repair

Codes that mean turn it off

These codes come from a flame, gas, venting or overheat safety. Leave the unit off and call a licensed technician rather than resetting it repeatedly:

Code by code

No code showing?

If the unit is not working and shows no code at all, start with the Tankless water heater, no hot water troubleshooter. It covers power, settings and supply problems that stop the control from running at all.

More error code tables

Sources