Rheem gas furnace code 11: failed ignition

The burners did not light, or the flame was not sensed. After each miss the inducer purges for 20 seconds and the furnace tries again; after four misses it goes into a one-hour lockout.

Photograph of a plain closed furnace cabinet with a metal duct in a tidy, softly lit basement
On this page
Code
11
Equipment
Rheem gas furnace
Models
(-)96V and (-)(-)96MDV series two-stage communicating condensing gas furnaces
What to do
Technician repair

What code 11 means

Rheem's Installation Instructions for 4 Position Condensing Two-Stage Communicating Gas Furnaces w/ECM Blower (-)96V Series (92-24161-124-08) lists 11 as failed ignition, for the (-)96V and (-)(-)96MDV series two-stage communicating condensing gas furnaces. A two-digit seven-segment display on the furnace control board shows the code. A steady character is a normal mode; a flashing number is a fault, and two faults can take turns on the display.

What usually causes it

The manual points to these causes for this code, roughly in the order a technician would rule them out:

  • The flame sensor rod is dirty or not properly connected.
  • The gas valve is turned off.
  • The igniter is not connected properly or its spark is in the wrong place.
  • Flame is not carrying from the first burner across to the others.
  • The furnace control board has failed.

What you can safely check

  1. Check that gas is reaching the house. If other gas appliances (stove, dryer) also do not work, the problem is the gas supply, so call your gas utility. Do not try to light anything or adjust the gas valve yourself.
  2. Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.
  3. Reset it once. Turn the unit off at its switch, wait a minute, and turn it back on, or use the reset the manual describes. One reset clears a passing glitch. If the same code comes back, stop resetting and book a technician.

When to call a technician

Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code 11 (the manual's first suspect is the flame sensor rod is dirty or not properly connected). That saves a diagnostic visit from starting at zero.

Step by step for this kind of problem

The Furnace not working troubleshooter walks through the symptom question by question and ends with a clear next step.

Other Rheem gas furnace codes

The full Rheem gas furnace code table lists every code with its meaning, and explains how to read and clear them.

Sources

  1. Rheem, Installation Instructions for 4 Position Condensing Two-Stage Communicating Gas Furnaces w/ECM Blower (-)96V Series (92-24161-124-08) pts.rheem.com
  2. Carrier, Furnace not turning on (help page) carrier.com
  3. U.S. Consumer Product Safety Commission, Carbon Monoxide Information Center cpsc.gov
  4. Noritz, How to troubleshoot a tankless water heater noritz.com