Rheem gas furnace code 45: low pressure switch open, inducer on high

The inducer is running at high speed but the low pressure switch has not closed, so the furnace cannot light. It keeps the inducer on for five minutes, rests, and tries again while heat is called for.

Photograph of a plain closed furnace cabinet with a metal duct in a tidy, softly lit basement
On this page
Code
45
Equipment
Rheem gas furnace
Models
(-)96V and (-)(-)96MDV series two-stage communicating condensing gas furnaces
What to do
Turn it off and call a pro

What code 45 means

Rheem's Installation Instructions for 4 Position Condensing Two-Stage Communicating Gas Furnaces w/ECM Blower (-)96V Series (92-24161-124-08) lists 45 as low pressure switch open, inducer on high, for the (-)96V and (-)(-)96MDV series two-stage communicating condensing gas furnaces. A two-digit seven-segment display on the furnace control board shows the code. A steady character is a normal mode; a flashing number is a fault, and two faults can take turns on the display.

What usually causes it

The manual points to these causes for this code, roughly in the order a technician would rule them out:

  • The air inlet or exhaust vent is blocked or wrongly terminated.
  • The vent is too long or has too many elbows.
  • The inducer has failed or is disconnected.
  • A pressure switch hose is loose, blocked, split or cut.
  • Loose wiring, a failed inducer relay on the board, or a failed pressure switch.
  • Gusty wind at the vent termination.

What you can safely check

  1. Look at the vent pipes outside. High-efficiency furnaces, boilers and tankless heaters breathe through plastic pipes on an outside wall or the roof. From the ground, check that snow, ice, leaves or a nest are not blocking either opening, and clear what you can reach safely.
  2. Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.

When to call a technician

Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code 45 (the manual's first suspect is the air inlet or exhaust vent is blocked or wrongly terminated). That saves a diagnostic visit from starting at zero.

Step by step for this kind of problem

The Furnace not working troubleshooter walks through the symptom question by question and ends with a clear next step.