Rheem gas furnace error codes
Rheem gas furnace code 59: water sensed in collector box
A sensor found water standing in the collector box, where condensate should drain away, for at least ten seconds. Gas heat stops while cooling keeps working, and repeats lead to a one-hour lockout.

On this page
- Code
- 59
- Equipment
- Rheem gas furnace
- Models
- (-)96V and (-)(-)96MDV series two-stage communicating condensing gas furnaces
- What to do
- Often an owner fix
What code 59 means
Rheem's Installation Instructions for 4 Position Condensing Two-Stage Communicating Gas Furnaces w/ECM Blower (-)96V Series (92-24161-124-08) lists 59 as water sensed in collector box, for the (-)96V and (-)(-)96MDV series two-stage communicating condensing gas furnaces. A two-digit seven-segment display on the furnace control board shows the code. A steady character is a normal mode; a flashing number is a fault, and two faults can take turns on the display.
What usually causes it
The manual points to these causes for this code, roughly in the order a technician would rule them out:
- The condensate drain or trap is blocked so water cannot drain.
- Damaged sensor wiring is touching the furnace sheet metal.
- A water sensor was pulled out of the collector box and its probe is touching metal.
What you can safely check
- Look at the condensate drain. Condensing equipment makes water that drains through a small hose or trap. A kinked hose, a full pump or water pooling under the unit can make it shut down. Straighten a kinked hose and empty a full pump reservoir; leave the trap itself to a technician.
- Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.
- Reset it once. Turn the unit off at its switch, wait a minute, and turn it back on, or use the reset the manual describes. One reset clears a passing glitch. If the same code comes back, stop resetting and book a technician.
When to call a technician
Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code 59 (the manual's first suspect is the condensate drain or trap is blocked so water cannot drain). That saves a diagnostic visit from starting at zero.
Step by step for this kind of problem
The Furnace not working troubleshooter walks through the symptom question by question and ends with a clear next step.
Related Rheem codes
Other Rheem gas furnace codes
The full Rheem gas furnace code table lists every code with its meaning, and explains how to read and clear them.