Rheem gas furnace error codes: what each one means

Rheem's manual for the (-)96V and (-)(-)96MDV series two-stage communicating condensing gas furnaces lists 32 codes. A two-digit seven-segment display on the furnace control board shows the code. A steady character is a normal mode; a flashing number is a fault, and two faults can take turns on the display.

Photograph of a plain closed furnace cabinet with a metal duct in a tidy, softly lit basement
On this page
Codes listed
32
Turn off and call a pro
6
Often an owner fix
10

How to read the code

The display is on the control board behind the blower door, and a dipswitch sets which way up it reads. If a code looks unfamiliar, it may simply be upside down. Normal mode letters such as h, H, c or F stay lit. A fault blinks on for about a second and off for half a second, repeating until it clears.

When a fault causes a lockout, the display takes turns between 10 (lockout) and the code for the cause, for example 10 and 11 after four failed lighting tries. On a communicating EcoNet system the thermostat shows active faults too, though some lighting faults only reach the homeowner screen after they repeat in one heat call.

A short press of the pushbutton on the board opens a status menu; the FL entry shows up to six stored faults from the past 168 powered hours, newest first. Holding the button for five seconds in that menu wipes the history, so write the codes down first.

Most lockouts reset on their own: five minutes for a pressure switch that will not prove, and one hour after failed ignition, repeated flame loss or unexpected flame. Once the cause is fixed, switching power off and on clears a lockout sooner. A hard lockout, such as a blower that is declared dead four times in one call, waits for a power reset.

Rheem gas furnace code table

Codes with a link have their own page with causes and the checks that fit that code.

Rheem gas furnace codes, from the Installation Instructions for 4 Position Condensing Two-Stage Communicating Gas Furnaces w/ECM Blower (-)96V Series (92-24161-124-08)
CodeWhat it meansWhat to do
0Standby. The furnace is idle: no fault and no call from the thermostat. During a blower off delay it also shows 0.Often an owner fix
H or hGas heat call. The thermostat is asking for gas heat: lowercase h for low stage, capital H for high stage.Often an owner fix
C or cCooling call. The thermostat is calling for cooling, low stage (c) or high stage (C).Often an owner fix
HP or hPHeat pump heating. A heat pump is heating the home through this furnace's blower, at low (hP) or high (HP) stage.Often an owner fix
FContinuous fan. The thermostat has the fan set to run all the time.Often an owner fix
dFDefrost. On a dual fuel system the heat pump is defrosting, and the furnace runs at low gas heat meanwhile.Often an owner fix
Cd or cdCooling with dehumidification. Cooling is running with dehumidification, so the blower moves less air to pull more moisture out.Often an owner fix
d1No model data. The control has no model data, the stored settings that tell it how to run the blower, so the furnace will not run in any mode.Technician repair
d4Memory card invalid or missing. The memory card is blank, corrupt or absent, but a backup copy of the model data on the control lets the furnace keep running normally.Technician repair
d6Motor size does not match memory card. The blower motor's horsepower does not match the memory card, so the control ignores the card and runs on its own stored data.Technician repair
10One-hour lockout. The control has stopped gas heat for one hour because of a repeated fault. It shows 10 in turn with the code for the cause; cooling and fan still work during the lockout.Technician repair
11Failed ignition. The burners did not light, or the flame was not sensed. After each miss the inducer purges for 20 seconds and the furnace tries again; after four misses it goes into a one-hour lockout.Technician repair
12Low flame sense. The flame signal is weak but heat still runs normally. If it gets weaker, it can become a flame loss (13) or failed ignition (11).Technician repair
13Flame lost after lighting. The burners lit and were sensed, then the flame signal dropped out during the heat call. The furnace purges, runs the blower off delay and tries again; five losses in one call cause a one-hour lockout.Technician repair
14Flame with gas valve off. The control sees flame at a time the gas valve should be closed. It runs the inducer and blower at high speed, ignores the thermostat until the flame is gone, then locks out for an hour.Turn it off and call a pro
22Main limit open. The main limit, an overheat switch on the heat exchanger, has opened, so gas heat stops while the blower keeps running. If it stays open past 150 seconds the control also shows 61 and treats the blower as dead.Turn it off and call a pro
30Low voltage fuse blown. The fuse that protects the 24 volt control circuit has opened, and the furnace will not run in any mode.Technician repair
33Rollout switch open. A manual reset rollout switch has opened because flames came out of the heat exchanger into the burner area. Gas heat stops and stays off until a technician fixes the cause and resets the switch.Turn it off and call a pro
44Low pressure switch closed with inducer off. The low pressure switch reads closed before the inducer has started, which it never should. The furnace will not start a heat cycle.Technician repair
45Low pressure switch open, inducer on high. The inducer is running at high speed but the low pressure switch has not closed, so the furnace cannot light. It keeps the inducer on for five minutes, rests, and tries again while heat is called for.Turn it off and call a pro
46Low pressure switch open, inducer on low. After the furnace dropped to low fire, the low pressure switch opened with the inducer on low speed. The gas valve shuts, the blower and inducer finish their delays, and the furnace tries to light again.Turn it off and call a pro
55High pressure switch closed with inducer off. The high pressure switch reads closed while the inducer is off, a sign it is stuck or bypassed. No heat cycle starts.Technician repair
57High pressure switch open, inducer on high. The high pressure switch stayed open with the inducer on high. Before lighting, the furnace waits and retries; once running, it drops to low fire and keeps heating if the low pressure switch stays closed, showing h and 57 in turn.Turn it off and call a pro
58Water sensor circuit open. The control cannot see the two water sensors in the condensate collector box, so gas heat is blocked. Cooling still works.Technician repair
59Water sensed in collector box. A sensor found water standing in the collector box, where condensate should drain away, for at least ten seconds. Gas heat stops while cooling keeps working, and repeats lead to a one-hour lockout.Often an owner fix
60Blower limited, still running. The blower hit its speed, torque or temperature limit but keeps running, so the furnace works almost normally.Often an owner fix
61Blower cannot run. The blower has failed or tripped its own thermal limit and cannot run, so the furnace shuts down in every mode. After four dead blower events in one heat call it goes into a hard lockout.Technician repair
66Blower overspeed. The blower motor is running at its power limit in its first few minutes, which usually means it is pushing against too much restriction.Often an owner fix
68Blower motor not communicating. The control board cannot talk to the blower motor. The code appears whenever there is a call for heat, cooling or fan, and the blower may not run.Technician repair
82Supply air sensor fault. The optional supply air temperature sensor was found and then read open or shorted. It is a low level fault and the furnace keeps running.Technician repair
84Outdoor air sensor fault. The optional outdoor air sensor was detected and then failed open or short. The furnace keeps operating and the code clears after three minutes.Technician repair
93Internal control fault. The control board found an unspecified internal fault and enters a hard lockout that cycling the thermostat call will not clear.Technician repair

Codes that mean turn it off

These codes come from a flame, gas, venting or overheat safety. Leave the unit off and call a licensed technician rather than resetting it repeatedly:

Code by code

No code showing?

If the unit is not working and shows no code at all, start with the Furnace not working troubleshooter. It covers power, settings and supply problems that stop the control from running at all.

More error code tables

Sources

  1. Rheem, Installation Instructions for 4 Position Condensing Two-Stage Communicating Gas Furnaces w/ECM Blower (-)96V Series (92-24161-124-08) pts.rheem.com
  2. Noritz, How to troubleshoot a tankless water heater noritz.com
  3. Carrier, Furnace not turning on (help page) carrier.com
  4. U.S. Consumer Product Safety Commission, Carbon Monoxide Information Center cpsc.gov
  5. ENERGY STAR, Maintenance Checklist (heating and cooling) energystar.gov