Rheem gas furnace code 13: flame lost after lighting
The burners lit and were sensed, then the flame signal dropped out during the heat call. The furnace purges, runs the blower off delay and tries again; five losses in one call cause a one-hour lockout.

On this page
- Code
- 13
- Equipment
- Rheem gas furnace
- Models
- (-)96V and (-)(-)96MDV series two-stage communicating condensing gas furnaces
- What to do
- Technician repair
What code 13 means
Rheem's Installation Instructions for 4 Position Condensing Two-Stage Communicating Gas Furnaces w/ECM Blower (-)96V Series (92-24161-124-08) lists 13 as flame lost after lighting, for the (-)96V and (-)(-)96MDV series two-stage communicating condensing gas furnaces. A two-digit seven-segment display on the furnace control board shows the code. A steady character is a normal mode; a flashing number is a fault, and two faults can take turns on the display.
What usually causes it
The manual points to these causes for this code, roughly in the order a technician would rule them out:
- The flame sensor rod is dirty, loose or its wire is damaged.
- The flame sensor is badly mounted or poorly grounded.
- The flame is unstable because burner parts, seals or the burner door gasket are not in place.
What you can safely check
- Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.
- Reset it once. Turn the unit off at its switch, wait a minute, and turn it back on, or use the reset the manual describes. One reset clears a passing glitch. If the same code comes back, stop resetting and book a technician.
When to call a technician
Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code 13 (the manual's first suspect is the flame sensor rod is dirty, loose or its wire is damaged). That saves a diagnostic visit from starting at zero.