Rheem gas furnace error codes
Rheem gas furnace code 60: blower limited, still running
The blower hit its speed, torque or temperature limit but keeps running, so the furnace works almost normally.

On this page
- Code
- 60
- Equipment
- Rheem gas furnace
- Models
- (-)96V and (-)(-)96MDV series two-stage communicating condensing gas furnaces
- What to do
- Often an owner fix
What code 60 means
Rheem's Installation Instructions for 4 Position Condensing Two-Stage Communicating Gas Furnaces w/ECM Blower (-)96V Series (92-24161-124-08) lists 60 as blower limited, still running, for the (-)96V and (-)(-)96MDV series two-stage communicating condensing gas furnaces. A two-digit seven-segment display on the furnace control board shows the code. A steady character is a normal mode; a flashing number is a fault, and two faults can take turns on the display.
What usually causes it
The manual points to these causes for this code, roughly in the order a technician would rule them out:
- Ductwork that is undersized or poorly laid out pushes static pressure past the published limit.
- Something is restricting airflow in the ducts.
- The air filter is dirty and needs cleaning or replacing.
What you can safely check
- Check the air filter. A clogged filter starves the system of air and can make a furnace overheat and shut itself down. Turn the furnace off, slide the filter out and hold it to the light; replace it if light barely passes through.
- Open the vents and clear the return grille. A furnace needs a free path for air: supply registers open in most rooms, and nothing (furniture, rugs, boxes) covering the large return grille. Too little airflow makes the heat exchanger run hot and trips the limit switch.
- Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.
When to call a technician
Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code 60 (the manual's first suspect is ductwork that is undersized or poorly laid out pushes static pressure past the published limit). That saves a diagnostic visit from starting at zero.
Step by step for this kind of problem
The Furnace not working troubleshooter walks through the symptom question by question and ends with a clear next step.
Related Rheem codes
Other Rheem gas furnace codes
The full Rheem gas furnace code table lists every code with its meaning, and explains how to read and clear them.
Sources