Rheem gas furnace code 14: flame with gas valve off

The control sees flame at a time the gas valve should be closed. It runs the inducer and blower at high speed, ignores the thermostat until the flame is gone, then locks out for an hour.

Photograph of a plain closed furnace cabinet with a metal duct in a tidy, softly lit basement
On this page
Code
14
Equipment
Rheem gas furnace
Models
(-)96V and (-)(-)96MDV series two-stage communicating condensing gas furnaces
What to do
Turn it off and call a pro

What code 14 means

Rheem's Installation Instructions for 4 Position Condensing Two-Stage Communicating Gas Furnaces w/ECM Blower (-)96V Series (92-24161-124-08) lists 14 as flame with gas valve off, for the (-)96V and (-)(-)96MDV series two-stage communicating condensing gas furnaces. A two-digit seven-segment display on the furnace control board shows the code. A steady character is a normal mode; a flashing number is a fault, and two faults can take turns on the display.

What usually causes it

The manual points to these causes for this code, roughly in the order a technician would rule them out:

  • The gas valve is stuck open.
  • Wiring sends 24 volts to the gas valve when it should not.
  • The furnace control is faulty and senses a flame that is not there.

What you can safely check

  1. Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.

When to call a technician

Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code 14 (the manual's first suspect is the gas valve is stuck open). That saves a diagnostic visit from starting at zero.

Step by step for this kind of problem

The Furnace not working troubleshooter walks through the symptom question by question and ends with a clear next step.

Other Rheem gas furnace codes

The full Rheem gas furnace code table lists every code with its meaning, and explains how to read and clear them.

Sources

  1. Rheem, Installation Instructions for 4 Position Condensing Two-Stage Communicating Gas Furnaces w/ECM Blower (-)96V Series (92-24161-124-08) pts.rheem.com
  2. Noritz, How to troubleshoot a tankless water heater noritz.com