Rheem gas furnace error codes
Rheem gas furnace code 61: blower cannot run
The blower has failed or tripped its own thermal limit and cannot run, so the furnace shuts down in every mode. After four dead blower events in one heat call it goes into a hard lockout.

On this page
- Code
- 61
- Equipment
- Rheem gas furnace
- Models
- (-)96V and (-)(-)96MDV series two-stage communicating condensing gas furnaces
- What to do
- Technician repair
What code 61 means
Rheem's Installation Instructions for 4 Position Condensing Two-Stage Communicating Gas Furnaces w/ECM Blower (-)96V Series (92-24161-124-08) lists 61 as blower cannot run, for the (-)96V and (-)(-)96MDV series two-stage communicating condensing gas furnaces. A two-digit seven-segment display on the furnace control board shows the code. A steady character is a normal mode; a flashing number is a fault, and two faults can take turns on the display.
What usually causes it
The manual points to these causes for this code, roughly in the order a technician would rule them out:
- The motor tripped on overheat from a blocked wheel or a failed bearing.
- The motor's power factor correction choke has failed.
- The model data is faulty or corrupted.
- Wiring to the motor or choke is damaged.
- The blower wheel is damaged or loose on the shaft.
- The motor has failed outright.
What you can safely check
- Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.
- Reset it once. Turn the unit off at its switch, wait a minute, and turn it back on, or use the reset the manual describes. One reset clears a passing glitch. If the same code comes back, stop resetting and book a technician.
When to call a technician
Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code 61 (the manual's first suspect is the motor tripped on overheat from a blocked wheel or a failed bearing). That saves a diagnostic visit from starting at zero.
Step by step for this kind of problem
The Furnace not working troubleshooter walks through the symptom question by question and ends with a clear next step.
Related Rheem codes
Other Rheem gas furnace codes
The full Rheem gas furnace code table lists every code with its meaning, and explains how to read and clear them.