Rheem gas furnace error codes
Rheem gas furnace code 68: blower motor not communicating
The control board cannot talk to the blower motor. The code appears whenever there is a call for heat, cooling or fan, and the blower may not run.

On this page
- Code
- 68
- Equipment
- Rheem gas furnace
- Models
- (-)96V and (-)(-)96MDV series two-stage communicating condensing gas furnaces
- What to do
- Technician repair
What code 68 means
Rheem's Installation Instructions for 4 Position Condensing Two-Stage Communicating Gas Furnaces w/ECM Blower (-)96V Series (92-24161-124-08) lists 68 as blower motor not communicating, for the (-)96V and (-)(-)96MDV series two-stage communicating condensing gas furnaces. A two-digit seven-segment display on the furnace control board shows the code. A steady character is a normal mode; a flashing number is a fault, and two faults can take turns on the display.
What usually causes it
The manual points to these causes for this code, roughly in the order a technician would rule them out:
- No line voltage at the motor's power plug, from a wiring problem or a loose pin.
- The low voltage control wiring between motor and board is faulty or not fully seated.
- The motor has failed and needs replacing.
What you can safely check
- Check that the front panel is seated. A switch behind the blower door cuts power when the panel is off or loose. Make sure the panel is pushed fully home and latched; do not tape or hold the switch closed.
- Check the power switch. Furnaces, boilers and powered water heaters have a service switch on or near the unit. Make sure it is on, and that the unit is plugged in if it has a cord.
- Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.
When to call a technician
Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code 68 (the manual's first suspect is no line voltage at the motor's power plug, from a wiring problem or a loose pin). That saves a diagnostic visit from starting at zero.
Step by step for this kind of problem
The Furnace not working troubleshooter walks through the symptom question by question and ends with a clear next step.
Related Rheem codes
Other Rheem gas furnace codes
The full Rheem gas furnace code table lists every code with its meaning, and explains how to read and clear them.