Rinnai tankless water heater error codes
Rinnai tankless water heater code 05: bypass valve fault
The bypass flow control device, a motorized valve that blends some cold water into the outgoing hot water, is not working as the board expects. On the RH180 hybrid the same number points at airflow problems.

On this page
- Code
- 05
- Equipment
- Rinnai tankless water heater
- Models
- SENSEI and non-SENSEI tankless: RU, RUR, RUC, RE, RX, CX, RL, V series (incl. V53De), RH180
- What to do
- Technician repair
What code 05 means
Rinnai's Troubleshooting Tankless Water Heater Diagnostic Codes (100000652) lists 05 as bypass valve fault, for the SENSEI and non-SENSEI tankless: RU, RUR, RUC, RE, RX, CX, RL, V series (incl. V53De), RH180. The code flashes as two digits or two letters on the temperature controller or the heater's front display, for example 11, 12 or LC. It stops flashing once the problem is fixed and the heater is supplying hot water again.
What usually causes it
The manual points to these causes for this code, roughly in the order a technician would rule them out:
- The bypass valve has failed or reads outside its resistance range.
- On RH180 models, a dirty air filter or a blocked or wrongly built vent.
- On RH180 models, debris in the fan, burner or heat exchanger fins.
What you can safely check
- Reset it once. Turn the unit off at its switch, wait a minute, and turn it back on, or use the reset the manual describes. One reset clears a passing glitch. If the same code comes back, stop resetting and book a technician.
- Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.
When to call a technician
Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code 05 (the manual's first suspect is the bypass valve has failed or reads outside its resistance range). That saves a diagnostic visit from starting at zero.
Step by step for this kind of problem
The Tankless water heater, no hot water troubleshooter walks through the symptom question by question and ends with a clear next step.
Related Rinnai codes
Other Rinnai tankless water heater codes
The full Rinnai tankless water heater code table lists every code with its meaning, and explains how to read and clear them.