Rinnai tankless water heater error codes
Rinnai tankless water heater code 54: exhaust too hot
Exhaust gas went over 163 °F. The heater first turns its burner down, and if the exhaust is still too hot after two minutes it shuts down and shows the code.

On this page
- Code
- 54
- Equipment
- Rinnai tankless water heater
- Models
- SENSEI and non-SENSEI tankless: RU, RUR, RUC, RE, RX, CX, RL, V series (incl. V53De), RH180
- What to do
- Turn it off and call a pro
What code 54 means
Rinnai's Troubleshooting Tankless Water Heater Diagnostic Codes (100000652) lists 54 as exhaust too hot, for the SENSEI and non-SENSEI tankless: RU, RUR, RUC, RE, RX, CX, RL, V series (incl. V53De), RH180. The code flashes as two digits or two letters on the temperature controller or the heater's front display, for example 11, 12 or LC. It stops flashing once the problem is fixed and the heater is supplying hot water again.
What usually causes it
The manual points to these causes for this code, roughly in the order a technician would rule them out:
- The vent terminal does not have the clearances it needs.
- The intake or exhaust is restricted, or the vent is too long.
- The gas type does not match the rating plate.
- Water coming into the heater is hotter than 160 °F.
- Scale inside the heat exchanger is causing hot spots and needs to be flushed out.
- The exhaust sensor or its wiring is faulty, or air is leaking at the fan.
What you can safely check
- Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.
- Look at the vent pipes outside. High-efficiency furnaces, boilers and tankless heaters breathe through plastic pipes on an outside wall or the roof. From the ground, check that snow, ice, leaves or a nest are not blocking either opening, and clear what you can reach safely.
When to call a technician
Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code 54 (the manual's first suspect is the vent terminal does not have the clearances it needs). That saves a diagnostic visit from starting at zero.
Step by step for this kind of problem
The Tankless water heater, no hot water troubleshooter walks through the symptom question by question and ends with a clear next step.
Related Rinnai codes
Other Rinnai tankless water heater codes
The full Rinnai tankless water heater code table lists every code with its meaning, and explains how to read and clear them.