Skip to content
WattsBack

Rinnai tankless water heater error codes

Rinnai tankless water heater code 71: gas solenoid valve fault

The control found a fault in the circuit for the gas solenoid valves, the electric valves that open to let gas reach the burner. The heater will not fire until the cause is fixed.

Photograph of a plain white wall-mounted tankless water heater with insulated pipes below it
On this page
Code
71
Equipment
Rinnai tankless water heater
Models
SENSEI and non-SENSEI tankless: RU, RUR, RUC, RE, RX, CX, RL, V series (incl. V53De), RH180
What to do
Turn it off and call a pro

What code 71 means

Rinnai's Troubleshooting Tankless Water Heater Diagnostic Codes (100000652) lists 71 as gas solenoid valve fault, for the SENSEI and non-SENSEI tankless: RU, RUR, RUC, RE, RX, CX, RL, V series (incl. V53De), RH180. The code flashes as two digits or two letters on the temperature controller or the heater's front display, for example 11, 12 or LC. It stops flashing once the problem is fixed and the heater is supplying hot water again.

What usually causes it

The manual points to these causes for this code, roughly in the order a technician would rule them out:

  • The DIP switch that shuts off the gas valve is in the On position.
  • Solenoid wiring is loose, broken or damaged, or the heater circuit is grounded.
  • Moisture in the gas valve, from a leaking heat exchanger or condensation running back from the vent.
  • A solenoid coil is open, or something inside the valve is blocking it.
  • The PC board has failed.

What you can safely check

  1. Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.

When to call a technician

Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code 71 (the manual's first suspect is the DIP switch that shuts off the gas valve is in the On position). That saves a diagnostic visit from starting at zero.

Step by step for this kind of problem

The Tankless water heater, no hot water troubleshooter walks through the symptom question by question and ends with a clear next step.

Other Rinnai tankless water heater codes

The full Rinnai tankless water heater code table lists every code with its meaning, and explains how to read and clear them.

Sources

  1. Rinnai, Troubleshooting Tankless Water Heater Diagnostic Codes (100000652) media.rinnai.us
  2. Rinnai, V53De Installation and Operation Manual, incl. diagnostic codes (100000561) media.rinnai.us
  3. Noritz, How to troubleshoot a tankless water heater noritz.com